4 / 45 page ![]() ADRF6820 Data Sheet Rev. C | Page 4 of 45 BWSEL01 BWSEL21 Parameter Test Conditions/Comments Min Typ Max Min Typ Max Unit LO to RF Leakage −82 −82 dBm RF to LO Leakage −67 −67 dBm LO to IF Leakage With respect to −5 dBm RF input power −78.5 −78.5 dBc RF to IF Leakage With respect to −5 dBm RF input power −49 −49 dBc Isolation2 Isolation between RFIN0 to RFIN1 −55 −55 dBc Isolation between RFIN1 to RFIN0 −55 −55 dBc fRF = 1900 MHz Conversion Gain Voltage gain +3 −3 dB Input P1dB 12 14.5 dBm Input IP3 33 35 dBm Input IP2 58 57 dBm Noise Figure Internal LO 18 20 dB External LO 17.5 19.5 dB LO to RF Leakage −75 −75 dBm RF to LO Leakage −64 −64 dBm LO to IF Leakage With respect to −5 dBm RF input power −64.5 −64.5 dBc RF to IF Leakage With respect to −5 dBm RF input power −43.5 −43.5 dBc Isolation2 Isolation between RFIN0 to RFIN1 −51 −51 dBc Isolation between RFIN1 to RFIN0 −39 −39 dBc fRF = 2100 MHz Conversion Gain Voltage gain +2.5 −3 dB Input P1dB 12 15.5 dBm Input IP3 37 34 dBm Input IP2 58 55 dBm Noise Figure Internal LO 18 20.5 dB External LO 18 20 dB LO to RF Leakage −72.5 −72.5 dBm RF to LO Leakage −62 −62 dBm LO to IF Leakage With respect to −5 dBm RF input power −71 −71 dBc RF to IF Leakage With respect to −5 dBm RF input power −45 −45 dBc Isolation2 Isolation between RFIN0 to RFIN1 −48.5 −48.5 dBc Isolation between RFIN1 to RFIN0 −36.5 −36.5 dBc fRF = 2650 MHz Conversion Gain Voltage gain +1.5 −4 dB Input P1dB 13 16.5 dBm Input IP3 33 33 dBm Input IP2 64 55 dBm Noise Figure Internal LO 19.5 22 dB External LO 19.5 21.5 dB LO to RF Leakage −70 −70 dBm RF to LO Leakage −57 −57 dBm LO to IF Leakage With respect to −5 dBm RF input power −76 −76 dBc RF to IF Leakage With respect to −5 dBm RF input power −46 −46 dBc Isolation2 Isolation between RFIN0 to RFIN1 −40.5 −40.5 dBc Isolation between RFIN1 to RFIN0 −33 −33 dBc 1 See Table 15. 2 This is the isolation between the RF inputs. An input signal was applied to RFIN0, while RFIN1 was terminated with 50 Ω. The IF signal amplitude was measured at the baseband output. Next, the internal switch was configured for RFIN1, and the feedthrough was measured as a delta from the fundamental. This difference is recorded as the isolation between RFIN0 and RFIN1. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |