| 数据搜索系统,热门电子元器件搜索 |
|
ADM1266ACPZ-R7 数据表(PDF) 59 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADM1266ACPZ-R7 数据表(HTML) 59 Page - Analog Devices |
|
59 / 62 page ![]() Data Sheet ADM1266 Rev. A | Page 59 of 62 STATUS_MFR_SPECIFIC_2 The STATUS_MFR_SPECIFIC_2 command returns two bytes data with contents as shown in Table 104. Table 104. Register 0xED—STATUS_MFR_SPECIFIC_2 Bits Bit Name R/W Description 15 BKUP_PASSWORD_CRC_FAULT R 0 means backup password CRC check passed, 1 means backup password CRC check failed. 14 BKUP_FIRMWARE_CRC_FAULT R 0 means backup firmware CRC check passed, 1 means backup firmware CRC check failed. 13 BKUP_PROJECT_CRC_FAULT R 0 means backup project CRC check passed, 1 means backup project CRC check failed. 12 BKUP_ABCONFIG_CRC_FAULT R 0 means backup ABConfig CRC check passed, 1 means backup ABConfig CRC check failed. 11 MAIN_PASSWORD_CRC_FAULT R 0 means main password CRC check passed, 1 means main password CRC check failed. 10 MAIN_FIRMWARE_CRC_FAULT R 0 means main firmware CRC check passed, 1 means main firmware CRC check failed. 9 MAIN_PROJECT_CRC_FAULT R 0 means main project CRC check passed, 1 means main project CRC check failed. 8 MAIN_ABCONFIG_CRC_FAULT R 0 means main ABConfig CRC check passed, 1 means main ABConfig CRC check failed. 7 BKUP_IAP_CRC_FAULT R 0 means backup IAP CRC check passed, 1 means the main IAP CRC check failed. 6 BKUP_MINI_IAP_CRC_FAULT R 0 means backup mini IAP CRC check passed, 1 = main mini IAP CRC check failed. 5 MAIN_IAP_CRC_FAULT R 0 means main IAP CRC check passed, 1 = main IAP CRC check failed. 4 MAIN_MINI_IAP_CRC_FAULT R 0 means main mini IAP CRC check passed, 1 = main mini IAP CRC check failed. 3 AVDD_UVLO_FAULT R 0 means no AVDD UVLO fault, 1 means AVDD UVLO fault occurred. 2 HARD_FAULT R 0 means no hard fault, 1 means hard fault occurred. 1 AB_SYNC_FAULT R 0 means sync pass, 1 means sync fail. 0 RUNNING_BACKUP_PROJECT R 0 means main project, 1 means backup project. REFRESH_CONFIGURATION This command is used to set refresh configuration and get the refresh status. Table 105. Register 0xF4—REFRESH_CONFIGURATION (for BLOCK R) Byte Byte Name R/W Description 0 Parameter length Block W Parameter data length—fixed to 1. 1 Parameter Block W 0x00: get auto-refresh interval. 0x01: get auto-refresh enabled/disabled status. Others: get all status, including refresh enable/disable, autorefresh enable/disable, refresh times, recalculate CRC error times, autorefresh interval. 0 Data length Block R Number of bytes of data for this block read (1 to 8). [8:1] Data Block R Parameters: 0x00: get autorefresh interval, Bytes[2:1] are the autorefresh interval. 0x01: get autorefresh enabled/disabled status. If Byte 1 is 0, autorefresh is disabled. Others: get all status, including refresh enable/disable, autorefresh enable/disable, refresh times, recalculate CRC error times, autorefresh interval, Bytes[8:1]: Byte Byte Name Description 1 Refresh status 0: refresh is done. 1: refresh is running. 2 Autorefreshing 0: autorefresh is disabled. 1: autorefresh is enabled. [4:3] Refresh count Refresh times. [6:5] Recalculate error count Recalculate error times. [8:7] Autorefresh interval Autorefresh interval, unit: day. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |