| 数据搜索系统,热门电子元器件搜索 |
|
PCA9641PW 数据表(PDF) 30 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
PCA9641PW 数据表(HTML) 30 Page - NXP Semiconductors |
|
30 / 55 page ![]() PCA9641 All information provided in this document is subject to legal disclaimers. © NXP Semiconductors N.V. 2015. All rights reserved. Product data sheet Rev. 2.1 — 27 October 2015 30 of 55 NXP Semiconductors PCA9641 2-channel I2C-bus master arbiter 13. General call software reset The Software Reset Call allows all the devices in the I2C-bus to be reset to the power-up state value through a specific formatted I2C-bus command. To be performed correctly, it implies that the I2C-bus is functional and that there is no device hanging the bus. The Software Reset sequence is defined as following: 1. A START command is sent by the I2C-bus master. 2. The reserved General Call I2C-bus address ‘0000 000’ with the R/W bit set to 0 (write) is sent by the I2C-bus master. 3. The device(s) acknowledge(s) after seeing the General Call address ‘0000 0000’ (00h) only. If the R/W bit is set to 1 (read), no acknowledge is returned to the I2C-bus master. 4. Once the General Call address has been sent and acknowledged, the master sends 1 byte. The value of the byte must be equal to 06h. The device acknowledges this value only. If the byte is not equal to 06h, the device does not acknowledge it. If more than 1 byte of data is sent, the device does not acknowledge any more. 5. Once the right byte has been sent and correctly acknowledged, the master sends a STOP command to end the Software Reset sequence: the slave device then resets to the default value (power-up value) and is ready to be addressed again within the specified bus free time. If the master sends a Repeated START instead, no reset is performed. 6. PCA9641 will issue the bus recovery procedure. The I2C-bus master must interpret a non-acknowledge from the slave device (at any time) as a ‘Software Reset Abort’. Slave device does not initiate a reset of its registers. 1000 0101 INT_MASK MB_LO MB_HI ID CONTR STATUS RT INT_ STATUS 1000 0110 MB_LO MB_HI ID CONTR STATUS RT INT_ STATUS INT_MASK 1000 0111 MB_HI ID CONTR STATUS RT INT_ STATUS INT_MASK MB_LO Table 15. Read/write the registers using Auto-Increment …continued Command code First data byte Second data byte Third data byte Fourth data byte Fifth data byte Sixth data byte Seventh data byte Eighth data byte Fig 18. Software Reset sequence aaa-008555 0 0 0 0 0 0 0 A S 0 SWRST Call I2C-bus address START condition R/W acknowledge from slave(s) 0 0 0 0 1 1 0 0 SWRST data = 06h A acknowledge from slave(s) P PCA9641 is reset. Registers are set to default power-up values. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |