14 / 55 page ![]() PCA9641 All information provided in this document is subject to legal disclaimers. © NXP Semiconductors N.V. 2015. All rights reserved. Product data sheet Rev. 2.1 — 27 October 2015 14 of 55 NXP Semiconductors PCA9641 2-channel I2C-bus master arbiter 5 IDLE_TIMER_DIS R/W After RES_TIME is expired, I2C-bus idle for more than 100 ms, PCA9641 will disconnect master from downstream bus and takes away its grant if this register bit is enabled. This IDLE_TIMER_DIS function also applies when there is a grant of a request with zero value on RES_TIME. 0* Normal operation. 1 Enable 100 ms idle timer. After reserve timer expires or if reserve timer is disabled, if the downstream bus is idle for more than 100 ms, the connection between master and downstream bus will be disconnected. 4 SMBUS_SWRST R/W Non-granted or granted master sends a soft reset, if this bit is set, PCA9641 sets clock LOW for 35 ms following reset of all register values to defaults. 0* Normal operation. 1 Enable sending SMBus time-out to downstream bus, after receiving a general call soft reset from master. 3 BUS_INIT R/W Bus initialization for PCA9641 sends one clock out and checks SDA signal. If SDA is HIGH, PCA9641 sends a ‘not acknowledge’ and a STOP condition. The BUS_INIT function is completed. If SDA is LOW, PCA9641 sends other clock out and checks SDA again. The PCA9641 will send out 9 clocks (maximum), and if SDA is still LOW, PCA9641 determines the bus initialization has failed. 0* Normal operation. 1 Start initialization on next bus connect function to downstream bus. 2 BUS_CONNECT R/W Connectivity between master and downstream bus; the internal switch connects I2C-bus from master to downstream bus only if LOCK_GRANT = 1. 0* Do not connect I2C-bus from master to downstream bus. 1 Connect downstream bus; the internal switch is closed only if LOCK_GRANT = 1. 1 LOCK_GRANT R only This is a status read only register bit. Lock grant status register bit indicates the ownership between reading master and the downstream bus. If this register bit is 1, the reading master has owned the downstream bus. If this register bit is zero, the reading master has not owned the downstream bus. 0* This master does not have a lock on the downstream bus. 1 This master has a lock on the downstream bus. Table 8. CONTR - Control register (pointer address 01h) bit description …continued POR = 00h. Legend: * default value Bit Symbol Access Value Description |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |