38 / 67 page ![]() SAP51 / SAP5S Datasheet © 2016 Integrated Device Technology, Inc. 38 January 28, 2016 5.8.5. Special Function of DSTBn In addition to the standard output function, the Data Strobe Pin serves as an external reset input for all operational modes of the SAP5. Pulling the DSTBn pin low for more than a minimum reset time generates an unconditioned reset of the SAP5, which is immediately followed by an initialization of the State Machine (EEPROM read out). For further information on the SAP5 reset behavior, especially in regard to the signal timing, see section 5.13. 5.9. Data and Parameter Port Configuration Data and Parameter Ports are configured by programming the IO_Code in the EEPROM (see Table 4.2). The configuration also depends on the Safety_Mode_Enable setting (see Table 4.4). Table 5.14 lists the different configurations selected by the IO_Code settings. NOTE: Table 5.14 refers to slaves that are not running in Safety Mode (for Safety Mode details, see section 5.18) The following configurations are possible: • OUT: output only; data are valid up to the next DSTBn/PSTBn strobe pulse • IN: input only; open-drain output is fixed at the high-impedance state • I/O: bi-directional port with timing according to Figure 5.2 and Figure 5.3 • INOUT: If IO_Code = 7, the Parameter Ports are configured as outputs after WPAR master calls and as inputs after DEXG master calls, respectively. • PASSIV: no input function and open-drain output is fixed at the high-impedance state If any of the D0 to D3 Data Ports is configured as OUT, the SAP5 slave answer to a DEXG master request contains the respective information bit I[3:0] received from the master. However, Parameter Ports P[3:0] are always operated as bi-directional, including a read-back of the actual port level as described in section 5.8. Table 5.14 Data and Parameter Port Configuration for Non-Safety-Mode Operation Note: See important table notes at the end of the table. IO_Code D0 D1 D2 D3 1) P0 P1 P2 P3 1) 0 IN IN IN IN OUT OUT OUT OUT 1 IN IN IN OUT OUT OUT OUT OUT 2 IN IN IN I/O OUT OUT OUT OUT 3 IN IN OUT OUT OUT OUT OUT OUT 4 IN IN I/O I/O OUT OUT OUT OUT 5 IN OUT OUT OUT OUT OUT OUT OUT 6 IN I/O I/O I/O OUT OUT OUT OUT 7 2) OUT OUT OUT OUT INOUT INOUT INOUT INOUT 8 OUT OUT OUT OUT OUT OUT OUT OUT 9 OUT OUT OUT IN OUT OUT OUT OUT A OUT OUT OUT I/O OUT OUT OUT OUT |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |