| 数据搜索系统,热门电子元器件搜索 |
|
SAP5SD-B-G1-R 数据表(PDF) 54 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
SAP5SD-B-G1-R 数据表(HTML) 54 Page - Renesas Technology Corp |
|
54 / 67 page ![]() SAP51 / SAP5S Datasheet © 2016 Integrated Device Technology, Inc. 54 January 28, 2016 In Master/Repeater Mode, the SAP5 provides an AS-i power-fail detector. It consists of a comparator directly connected to the LTGP pin that generates a logic signal if the voltage at the LTGP pin drops below VAPF (refer to Table 5.28). A subsequent digital signal processing of the comparator output signal is performed as follows: • An anti-bouncing filter removes any signal states shorter than 6 µs. This is to eliminate the influence of AS-i telegrams that are added onto the AS-i DC voltage. • An additional anti-bouncing filter with different filter times for activation and deactivation of the power-fail signal removes short power-fail pulses. • The AS-i power-fail signal is provided directly active high as the signal APF. • Additionally, in Master Mode, the AS-i power-fail signal modulates the RX_DAT signal; whereas the active state is signaled by logic high level. Table 5.28 Master/Repeater Mode Parameter Parameter Symbol Min Max Unit Loopback time in Master Mode 1) tLOOPBACK 4.9 6.5 µs AS-i Power Fail voltage threshold VAPF 21.5 23.5 V Minimum activation time for signaling of AS-i Power Fail by use of the RX_DAT signal 2) tAPF_RX_DAT 640 704 µs Release time of the AS-i Power Fail state within the RX_DAT signal 2) tAPF_ON_RX_DAT 64 µs Minimum activation time for signaling of AS-i Power Fail by use of the APF signal 2) tAPF_APF 704 768 µs AS-i Power Fail hold time tHOLD_APF 64 µs Delay time after return of the AS-i power tAPF_OFF 64 128 µs Break time in case of an erroneous AS-i signal tBREAK 9 15 µs 1) Loopback time is the time difference between an edge in the MAN code of signal TX_DAT and the corresponding edge in the Manchester-code of the signal RX_DAT. The voltage trigger level for measurement of the edge time is defined by VU5R/2. The actual loopback time may be adjusted by programming the ID_Code_Extension_2 EEPROM register as described in Table 5.27. 2) In Master Mode, the AS-i Power Fail state is already signaled by the RX_DAT signal as soon as the power fail condition is true for a time more than tAPF_RX_DAT. However, in order to start the APF minimum hold state (tHOLD_APF), the power fail condition must remain true for another time period defined by tAPF_ON_RX_DAT. Otherwise, the RX_DAT signal returns to its idle state (logic low) immediately. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |