4 / 81 page ![]() STLC1502 4/81 200 MHz To change the D950 master clock frequency the following procedure must be followed: 1) Disable the D950 clock, by resetting the DCLK bit in the control register of the MISC Control register. 2) Wait 10 ARM cycles 3) Select a new D950 master clock, by writing the MISC Status register. 4) Wait 4 ms 5) Disable the D950 clock, by setting the DCLK bit in the MISC Control register. An Internal divider provides an internal PCM clock, 2083 KHz, that is not exactly the standard 2048 KHz. - An external PCM clock frequency can be applied using a dedicated crystal or oscillator, to provide exactly 8KHz synch and sampling clock on the PCM bus. (External pins configuration Testsel[3:0] at [0011]). The PCM clock rate can be selected via software to achieve the following values: 1536 (24 Ch.) 2048 (32 Ch.) 4096 (64 Ch.) 8192 KHz (128 Ch.). - The PCM clock and Frame synch signals can be selected as inputs or outputs, by programming the con- trol register in the miscellaneous block. 4.0 Pin Descriptions The STLC1502 will be delivered in: • PQFP 208 Pins |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|