数据搜索系统,热门电子元器件搜索
  Chinese  ▼
ALLDATASHEETCN.COM

X  

H8/3028F 数据表(PDF) 520 Page - Renesas Technology Corp

部件名 H8/3028F
功能描述  Renesas 16-Bit Single-Chip Microcomputer H8 Family/H8/300H Series
PDF  923 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
制造商  RENESAS [Renesas Technology Corp]
网页  http://www.renesas.com
标志 RENESAS - Renesas Technology Corp

H8/3028F 数据表(HTML) 520 Page - Renesas Technology Corp

Back Button H8/3028F Datasheet HTML 516Page - Renesas Technology Corp H8/3028F Datasheet HTML 517Page - Renesas Technology Corp H8/3028F Datasheet HTML 518Page - Renesas Technology Corp H8/3028F Datasheet HTML 519Page - Renesas Technology Corp H8/3028F Datasheet HTML 520Page - Renesas Technology Corp H8/3028F Datasheet HTML 521Page - Renesas Technology Corp H8/3028F Datasheet HTML 522Page - Renesas Technology Corp H8/3028F Datasheet HTML 523Page - Renesas Technology Corp H8/3028F Datasheet HTML 524Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 520 / 923 page
background image
Rev. 2.00, 09/03, page 490 of 890
In receiving, the SCI operates as follows:
• The SCI monitors the communication line. When it detects a start bit (0 bit), the SCI
synchronizes internally and starts receiving.
• Receive data is stored in RSR in order from LSB to MSB.
• The parity bit and stop bit are received.
After receiving these bits, the SCI carries out the following checks:
 Parity check: The number of 1s in the receive data must match the even or odd parity
setting of in the O/
E bit in SMR.
 Stop bit check: The stop bit value must be 1. If there are two stop bits, only the first is
checked.
 Status check: The RDRF flag must be 0, indicating that the receive data can be transferred
from RSR into RDR.
If these all checks pass, the RDRF flag is set to 1 and the received data is stored in RDR. If
one of the checks fails (receive error*), the SCI operates as shown in table 13.11.
Note: * When a receive error occurs, further receiving is disabled. In receiving, the RDRF flag is
not set to 1. Be sure to clear the error flags to 0.
• When the RDRF flag is set to 1, if the RIE bit is set to 1 in SCR, a receive-data-full interrupt
(RXI) is requested. If the ORER, PER, or FER flag is set to 1 and the RIE bit in SCR is also
set to 1, a receive-error interrupt (ERI) is requested.
Table 13.11 Receive Error Conditions
Receive Error Abbreviation Condition
Data Transfer
Overrun error ORER
Receiving of next data ends while
RDRF flag is still set to 1 in SSR
Receive data is not transferred
from RSR to RDR
Framing error FER
Stop bit is 0
Receive data is transferred from
RSR to RDR
Parity error
PER
Parity of received data differs from
even/odd parity setting in SMR
Receive data is transferred from
RSR to RDR



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com