| 数据搜索系统,热门电子元器件搜索 |
|
AD9520-2/PCBZ 数据表(PDF) 41 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9520-2/PCBZ 数据表(HTML) 41 Page - Analog Devices |
|
41 / 84 page ![]() AD9520-2 Rev. 0 | Page 41 of 84 After leaving holdover, the loop then reacquires lock, and the LD pin must go high (if 0x01D[3] = 1) before it can reenter holdover. The holdover function always responds to the state of the currently selected reference (0x01C). If the loop loses lock during a reference switchover (see the Reference Switchover section), holdover is triggered briefly until the next reference clock edge at the PFD. The following registers affect the automatic/internal holdover function: • 0x018[6:5]—lock detect counter. This changes how many consecutive PFD cycles with edges inside the lock detect window are required for the DLD indicator to indicate lock. This impacts the time required before the LD pin can begin to charge as well as the delay from the end of a holdover event until the holdover function can be reengaged. • 0x018[3]—disable digital lock detect. This bit must be set to a 0 to enable the DLD circuit. Internal/automatic holdover does not operate correctly without the DLD function enabled. • 0x01A[5:0]—lock detect pin control. Set this to 000100b to put it in the current source lock detect mode if using the LD pin comparator. Load the LD pin with a capacitor of an appropriate value. • 0x01D[3]—LD pin comparator enable. 1 = enable; 0 = disable. When disabled, the holdover function always senses the LD pin as high. • 0x01D[1]—external holdover control. • 0x01D[0]—holdover enable. If holdover is disabled, both external- and automatic/ internal holdover are disabled. In the following example, automatic holdover is configured with • Automatic reference switchover, prefer REF1. • Digital lock detect: five PFD cycles, high range window. • Automatic holdover using the LD pin comparator. The following registers are set (in addition to the normal PLL registers): • 0x018[6:5] = 00b; lock detect counter = five cycles. • 0x018[4] = 0b; digital lock detect window = high range. • 0x018[3] = 1b; disable DLD normal operation. • 0x01A[5:0] = 000100b; program LD pin control to current source lock detect mode. • 0x01C[4] = 1b; enable automatic switchover. • 0x01C[3] = 0b; prefer REF1. • 0x01C[2:1] = 11b; enable REF1 and REF2 input buffers. • 0x01D[3] = 1b; enable LD pin comparator. • 0x01D[1] = 0b; disable external holdover mode and use automatic/internal holdover mode. • 0x01D[0] = 1b; enable holdover. Frequency Status Monitors The AD9520 contains three frequency status monitors that are used to indicate if the PLL reference (or references in the case of single-ended mode) and the VCO have fallen below a threshold frequency. A diagram showing their location in the PLL is shown in Figure 47. The PLL reference monitors have two threshold frequencies: normal and extended (see Table 17). The reference frequency monitor thresholds are selected in 0x01F. PROGRAMMABLE N DELAY CLK CLK REF1 REF2 BUF STATUS STATUS VCO STATUS REFERENCE SWITCHOVER REF_SEL CPRSET VCP VS GND RSET DISTRIBUTION REFERENCE REFMON CP STATUS LD P, P + 1 PRESCALER A/B COUNTERS N DIVIDER BYPASS LF LOW DROPOUT REGULATOR (LDO) PHASE FREQUENCY DETECTOR LOCK DETECT CHARGE PUMP HOLD 0 1 DIVIDE BY 1, 2, 3, 4, 5, OR 6 ZERO DELAY BLOCK FROM CHANNEL DIVIDER 0 VS_DRV REFIN OPTIONAL REFIN Figure 47. Reference and VCO Status Monitors |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |