| 数据搜索系统,热门电子元器件搜索 |
|
ADP1048ARQZ-R7 数据表(PDF) 26 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADP1048ARQZ-R7 数据表(HTML) 26 Page - Analog Devices |
|
26 / 84 page ![]() ADP1047/ADP1048 Data Sheet Rev. 0 | Page 26 of 84 STANDARD PMBus FLAGS When the corresponding bit of a standard PMBus flag is set in the STATUS_WORD or STATUS_BYTE register, the programmed action takes place as shown in Figure 25. Figure 25 shows the bits in the six standard PMBus fault response registers: Register 0x41, Register 0x45, Register 0x50, Register 0x56, Register 0x5A, and Register 0x5C. All six PMBus fault response registers follow the same format. For more infor- mation, see the PMBus Fault Flag Response section. FAULT CLEARED 11 = DISABLE OUTPUT FAULT NOT CLEARED OUTPUT DISABLED RESPONSE (BITS[7:6]) RETRY SETTING (BITS[5:3]) DELAY TIME (BITS[2:0]) NORMAL OPERATION 00 = DO NOTHING FLAGS ARE IGNORED IF BLANKED SOFT START DELAY TIME (BITS[2:0]) SHUT DOWN RETRY SETTING (BITS[5:3]) 000 = NO RETRIES (OFF) 001 TO 110 = TRY 1 TO 6 TIMES 111 = RETRY FOREVER IF FLAG STILL ACTIVE 01 = SHUT DOWN (AFTER DEBOUNCE) 10 = IMMEDIATE SHUTDOWN Figure 25. Standard PMBus Fault Response Table 12. Summary of Standard PMBus Flags Implemented on the ADP1047/ADP1048 Name Address Description Action STATUS_BYTE (0x78) PSON_OFF 0x78[6] Power supply on signal: this flag indicates that the PSON signal (hardware or software) is inactive. VOUT_OV 0x78[5] General output overvoltage fault. This flag is a combination (OR) of any output overvoltage flag: Register 0x7A[7] and Register 0xFE80[4] (FAST_OVP). Programmable VIN_UV 0x78[3] General input undervoltage fault (same data as in Register 0x7C[4]). Programmable TEMPERATURE 0x78[2] Temperature fault or warning. Programmable CML 0x78[1] Communications, memory, or logic fault. NONE_OF_THE_ABOVE 0x78[0] A fault or warning not listed in Register 0x78[7:1]. STATUS_WORD (0x79) VOUT 0x79[15] Any fault or warning on the output voltage (overvoltage, undervoltage, fast OVP, or accurate OVP). INPUT 0x79[13] Input voltage, input current, or input power fault or warning (same data as in Register 0x7C, Bits[7:0]). MFR 0x79[12] Manufacturer-specific fault or warning (same data as in Register 0xFE80, Register 0xFE81, and Register 0xFE82). POWER_GOOD# 0x79[11] Power good. This flag is a programmable combination of other internal flags and refers to the condition of the output voltage. This flag sets the PGOOD pin. The POWER_GOOD# flag is an inverted version of the PGOOD pin. PGOOD pin UNKNOWN 0x79[8] A fault or warning not listed in Bits[15:1]. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |