18 / 86 page ![]() NXP Semiconductors PCA2131 Nano-power highly accurate RTC with integrated quartz crystal for automotive applications PWRMNG[2:0] Function 000 battery switch-over function is enabled in standard mode; battery low detection function is enabled 001,010 battery switch-over function is enabled in standard mode; battery low detection function is disabled 011 battery switch-over function is enabled in direct switching mode; battery low detection function is enabled 100,101 battery switch-over function is enabled in direct switching mode; battery low detection function is disabled 110,111 [1] [2] battery switch-over function is disabled, only one power supply (VDD); battery low detection function is disabled Table 22. Power management control bit description [1] Default value. [2] When the battery switch-over function is disabled, the device works only with the power supply VDD. VBAT must be put to ground and the battery low detection function is disabled. 7.5.1 Battery switch-over function PCA2131 has a backup battery switch-over circuit which monitors the main power supply VDD. When a power failure condition is detected, it automatically switches to the backup battery. One of two operation modes can be selected: Standard mode - the power failure condition happens when: VDD < VBAT AND VDD < Vth(sw)bat Vth(sw)bat is the battery switch threshold voltage. Typical value is 2.5 V. The battery switch-over in standard mode works only for VDD > 2.5 V. Applying back-up battery voltage to VBAT without applying VDD supply will not power on the device; only when VDD main power is supplied the device will start operating. Direct switching mode - the power failure condition happens when VDD < VBAT. Direct switching from VDD to VBAT without requiring VDD to drop below Vth(sw)bat When a power failure condition occurs and the power supply switches to the battery, the following sequence occurs: 1. The battery switch flag BF (register Control_3) is set to logic 1. 2. An interrupt is generated if the control bit BIE (register Control_3) is enabled (see Section 7.13.6). 3. If the control bit BTSE (register Control_3) is logic 1, the timestamp 4 registers store the time and date when the battery switch occurred (see Section 7.12.4). 4. The battery switch flag BF is cleared by command; it must be cleared to clear the interrupt. The interface and CLKOUT output are disabled in battery backup operation: • Interface inputs are not recognized, preventing extraneous data being written to the device • Interface outputs are high-impedance PCA2131 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2021. All rights reserved. Product data sheet Rev. 1.0 — 26 July 2021 18 / 86 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |