| 数据搜索系统,热门电子元器件搜索 |
|
ST7LITE49M 数据表(PDF) 42 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ST7LITE49M 数据表(HTML) 42 Page - STMicroelectronics |
|
42 / 188 page ![]() Supply, reset and clock management ST7LITE49M 42/188 7.4 System integrity management (SI) The System Integrity Management block contains the Low voltage Detector (LVD) and Auxiliary Voltage Detector (AVD) functions. It is managed by the SICSR register. Note: A reset can also be triggered following the detection of an illegal opcode or prebyte code. Refer to Section 12.2.1 on page 139 for further details. 7.4.1 Low Voltage Detector (LVD) The Low Voltage Detector function (LVD) generates a static reset when the VDD supply voltage is below a VIT-(LVD) reference value. This means that it secures the power-up as well as the power-down keeping the ST7 in reset. The VIT-(LVD) reference value for a voltage drop is lower than the VIT+(LVD) reference value for power-on in order to avoid a parasitic reset when the MCU starts running and sinks current on the supply (hysteresis). The LVD Reset circuitry generates a reset when VDD is below: ● VIT+(LVD)when VDD is rising ● VIT-(LVD) when VDD is falling The LVD function is illustrated in Figure 17. The voltage threshold can be configured by option byte to be low, medium or high. See Section 14.1 on page 175. Provided the minimum VDD value (guaranteed for the oscillator frequency) is above VIT-(LVD), the MCU can only be in two modes: ● Under full software control ● In static safe reset In these conditions, secure operation is always ensured for the application without the need for external reset hardware. During a Low Voltage Detector Reset, the RESET pin is held low, thus permitting the MCU to reset other devices. Note: Use of LVD with capacitive power supply: with this type of power supply, if power cuts occur in the application, it is recommended to pull VDD down to 0V to ensure optimum restart conditions. Refer to circuit example in Figure 96 on page 171 and note 4. The LVD is an optional function which can be selected by option byte. See Section 14.1 on page 175. It allows the device to be used without any external RESET circuitry. If the LVD is disabled, an external circuitry must be used to ensure a proper power-on reset. It is recommended to make sure that the VDD supply voltage rises monotonously when the device is exiting from Reset, to ensure the application functions properly. Make sure that the right combination of LVD and AVD thresholds is used as LVD and AVD levels are not correlated. Refer to section Section 13.3.2 on page 145 and Section 13.3.3 on page 146 for more details. Caution: If an LVD reset occurs after a watchdog reset has occurred, the LVD will take priority and will clear the watchdog flag. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |