21 / 248 page ![]() TMP93CS40/TMP93CS41 2004-02-10 93CS40-19 (1) Switching from NORMAL to SLOW mode When the resonator is connected to the X1 and X2, or to the XT1 and XT2 pins, the warm-up timer is used to change the operation frequency after stable oscillation is attained. The warm-up time can be selected by WDMOD<WARM>. This starting and stopping of the warm-up timer are performed by programming as in the following examples 1 and 2. Note 1: The warm-up timer is also used as a watchdog timer. So when it is to be used as a warm-up timer, the watchdog timer function must be disabled. Note 2: In the case of using an oscillator (not resonator) with stable oscillation, a warm-up timer is not needed. Note 3: The warm-up timer is operated by an oscillation clock. Therefore there is an error in, warm-up time. Table 3.3.2 Warm-up Time Warm-up time WDMOD<WARM> Change to NORMAL (fc) Change to SLOW (fs) 0 (214/frequency) 0.8192 ms 500 ms 1 (2 16/frequency) 3.2768 ms 2000 ms at fc = 20 MHz, fs = 32.768 kHz |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|