151 / 172 page ![]() STA382BWS Register description: Sound Terminal compatibility Doc ID 022784 Rev 1 151/172 To be noted that once the check is performed, and the tristate released, the short protection is not active anymore until the next EAPD 0->1 toggling which means that shorts that happened during normal operation cannot be detected. To be noted that register 0x47 is meaningful only after the EAPD bit is set to ‘1’ at least once. The short-circuit protections implemented are effective only in BTL configuration, and they must not be activated if a single ended-application scheme is needed. Figure 42. Short-circuit detection timing diagram (no short detected) In Figure 42 the short protection timing diagram is shown. The time information is expressed in clock cycles, where the clock frequency is defined as in section 7.1.1. The gray color is used for the SHOKx bits to indicate that the bits are carrying the status of the previous EAPD 0->1 toggling (to be noted that after reset this state is meaningless since no EAPD transition occurs). GND-related SHOK bits are updated as soon as the gnd test is completed, VCC bits are updated after the vcc test is completed, and the SOUT bit is updated after the shorted output test is completed. The gnd test, vcc test and output test are always run (if the SHEN bit active and EAPD is toggled to ‘1’), and only if both tests are successful (no short) do the bridge outputs leave the tristate (indicated by dotted lines in the figure). If one of the three tests (or all) fail, the power bridge outputs are kept in tristate until the procedure is restarted with a new EAPD toggling. In this figure EAPD is intended to be bit 7 of register 0x05. EAPD OUT1A OUT1B OUT2A OUT2B SHOK1[7:4] SHOK1[3:0] SHOK2[0] t s e t t r o h S f o d n E t s e t c c v t r a t S t s e t d n g t r a t S 44 cycles 50005 cy c les 50005 cy cles 1c yc le Start o ut test TBD cycles Obsolete Product(s) - Obsolete Product(s) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |