  STPM098C Datasheet HTML 1Page - STMicroelectronics STPM098C Datasheet HTML 2Page - STMicroelectronics STPM098C Datasheet HTML 3Page - STMicroelectronics STPM098C Datasheet HTML 4Page - STMicroelectronics STPM098C Datasheet HTML 5Page - STMicroelectronics STPM098C Datasheet HTML 6Page - STMicroelectronics STPM098C Datasheet HTML 7Page - STMicroelectronics STPM098C Datasheet HTML 8Page - STMicroelectronics STPM098C Datasheet HTML 9Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 5 / 110 page
background image
Table 1. Pins list description
#
Name
Description
Type Class
1
PWM8/PWM1_L2
Loop 1 phase 8 pulse width modulation output. Keep floating if not used
O
Local
Loop 2 phase 1 pulse width modulation output. Keep floating if not used
2
PWM7/PWM2_L2
Loop 1 phase 7 pulse width modulation output. Keep floating if not used
O
Local
Loop 2 phase 2 pulse width modulation output. Keep floating if not used
3
PWM6/PWM3_L2
Loop 1 phase 6 pulse width modulation output. Keep floating if not used
O
Local
Loop 2 phase 3 pulse width modulation output. Keep floating if not used
4
PWM5/PWM4_L2
Loop 1 phase 5 pulse width modulation output. Keep floating if not used
O
Local
Loop 2 phase 4 pulse width modulation output. Keep floating if not used
5
PWM4
Loop 1 phase 4 pulse width modulation output. Keep floating if not used
O
Local
6
PWM3
Loop 1 phase 3 pulse width modulation output. Keep floating if not used
O
Local
7
PWM2
Loop 1 phase 2 pulse width modulation output. Keep floating if not used
O
Local
8
PWM1
Loop 1 phase 1 pulse width modulation output. Keep floating if not used
O
Local
9
SM_DATA
PMBus™ bidirectional serial data line. Connect to GND if not used
I/O
Local
10
SM_CLK
PMBus™ serial clock line. Connect to GND if not used
I/O
Local
11
SM_ALERT
PMBus™ alert line (active low). Keep floating if not used
O
Local
12
FAULT
System fault status output (active low). Keep floating if not used
O
Local
13
VRHOT
External temperature alert indicator output (active low). Keep floating if not used
O
Local
14
POWERIN_ALERT
Input power alert indicator output (active low). Keep floating if not used
O
Local
15
VRRDY2
Voltage regulator ready output for loop 2 (active high). Keep floating if not used
O
Local
16
VRRDY1
Voltage regulator ready output for loop 1 (active high). Keep floating if not used
O
Local
17
TDI (debug only)
JTAG interface test data in (connect to GND in final application)
I
NA
18
TCK (debug only)
JTAG interface test clock (connect to GND in final application)
I
NA
19
TMS (debug only)
JTAG interface test mode select (connect to VCC in final application)
I
NA
20
TDO (debug only)
JTAG interface test data out (leave unconnected in final application)
O
NA
21
AUX_SENSE
Auxiliary voltage sense input. Connect to GND if not used
I
Local
22 TM_EN (debug only) Device test mode entry (connect to GND in final application)
I
NA
23
VR_EN2
Enable input for loop 2 (active high). Connect to GND if not used
I
Local
24
VR_EN1
Enable input for loop 1 (active high). Connect to GND if not used
I
Local
25
VSEN1
Voltage sense input for loop 1. Connect to GND if not used
I
Local
26
VRTN1
Voltage sense return input for loop 1. Connect to GND if not used
I
Local
27
ISEN1
Phase 1 current sense input. Keep floating if not used
I
Local
28
ISEN2
Phase 2 current sense input. Keep floating if not used
I
Local
29
ISEN3
Phase 3 current sense input. Keep floating if not used
I
Local
30
ISEN4
Phase 4 current sense input. Keep floating if not used
I
Local
31
ISEN5/ISEN4_L2
Phase 5 current sense input. Keep floating if not used
I
Local
Loop 2 phase 4 current sense input. Keep floating if not used
32
ISEN6/ISEN3_L2
Phase 6 current sense input. Keep floating if not used
I
Local
Loop 2 phase 3 current sense input. Keep floating if not used
33
ISEN7/ISEN2_L2
Phase 7 current sense input. Keep floating if not used
I
Local
Loop 2 phase 2 current sense input. Keep floating if not used
STPM098C
Block diagram and pins description
DS14440 - Rev 1
page 5/110



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com