37 / 110 page ![]() 3.5.1 Loop start/stop sequence STPM098C loop controllers allow different methods to Start/Stop regulation by properly configuring PMBus™ standard commands: • OPERATION • ON_OFF_CONFIG The OPERATION command is used to enable/disable the n-th control loop in conjunction with the VR_ENn pin and the MFR_VR_EN command. This command defines also whether the n-th control loop has to work in margin mode (LOW/HIGH) or in NO margin mode. • OPERATION[7:6] = 00, the control loop is directly disabled. • OPERATION[5:4] = 00, the control loop is enabled in NO margin mode. • OPERATION[5:4] = 01, the control loop is enabled in LOW margin mode. • OPERATION[5:4] = 10, the control loop is enabled in HIGH margin mode. Independently from bit [5:4] configuration, if an output overvoltage or undervoltage fault is detected STPM098C treats this fault as programmed in the related fault response command. The ON_OFF_CONFIG command is used to configure the combination of VR_ENn pin input and serial bus OPERATION and MFR_VR_EN commands needed to enable/disable the n-th control loop. • ON_OFF_CONFIG[4:2] = 0xx, the loop is enabled and operates any time bias power is available regardless of the setting of bits [3:2]. • ON_OFF_CONFIG[4:2] = 110, the control loop is enabled/disabled only by OPERATION command. • ON_OFF_CONFIG[4:2] = 101, the control loop is enabled/disabled only by logic OR between VR_ENn pin and MFR_VR_EN command. • ON_OFF_CONFIG[4:2] = 111, the control loop is enabled when both the OPERATION command AND the VR_ENn pin ORMFR_VR_EN are commanding the loop to be on. If either an OPERATION command OR the VR_ENn pin AND MFR_VR_EN commands the control loop to be off. Note: For both OPERATION and ON_OFF_CONFIG settings: • Any value not listed is an invalid command. • Any bit not listed in the table is a don`t care. The ON_OFF_COMMAND operations can be depicted in the following simplified block diagram: Figure 28. ON_OFF_CONFIG operation simplified block diagram OPERATION ON_OFF_CONFIG Enable to Loop Controller 0XX 110 101 111 bit<4:2> VR_EN (Pin) MFR_VR_EN INT_RST STPM098C loop can be configured to separately start each control loop by adjusting the relative delay through a dedicated PMBus™ command as follows: TONDELAY=ΔLSB×TONDELAY8:0 (1) STPM098C Functional description DS14440 - Rev 1 page 37/110 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |