12 / 110 page ![]() Table 7. VCC monitor electrical characteristic Symbol Parameter Test condition Min Typ Max Unit Notes VCC_uv_th VCC undervoltage threshold 4 4.19 4.4 V Comparator output low to high VCC_uv_hys VCC undervoltage hysteresis 60 120 180 mV VCC_ov_th VCC overvoltage threshold 5.3 5.5 5.7 V Comparator output Low to high VCC_ov_hys VCC overvoltage hysteresis 25 70 125 mV T_vcc_uv_flt VCC undervoltage 9 10 11 us Digital filter T_vcc_ov_flt VCC overvoltage 9 10 11 us Digital filter T_apor_ltoh_flt POR ANA Low to high state filter time 3.5 5.5 7.5 μs Analog filter T_apor_htol_flt POR ANA high to Low state filter time 7 11 15 μs Analog filter Figure 6. VCC power supply operative range t VCC VCC_OV (internal signal) VCC_UV (internal signal) OV VCC_OV_TH TPOR_LTOH_flt UV UV OPERATIVE VCC_UV_TH VCC_OV_HYS VCC_UV_HYS TPOR_HTOL_flt 1 ≈2.5V POR_ANA SHUTDOWN SHUTDOWN 2 3 4 OPERATIVE TPOR_LTOH_flt TPOR_HTOL_flt TVCC_OV_flt TVCC_OV_flt TVCC_UV_flt TVCC_UV_flt Note: 1. 0 V ≤ VCC ≤ 2.5 V(1) STPM098C is shut down. Internal reference voltage/currents levels are shut down. Internal registers are under reset. 2. 2.5 V ≤ VCC ≤ VCC_uv_th(Max) + VCC_uv_hyst (max) VCC is in undervoltage and SAFE_HIZ is established. Internal reference voltage/currents levels are degraded. Internal registers are out of reset. 3. VCC_uv_th ≤ VCC ≤ VCC_ov_th Internal supply and reference voltage/currents are available. Internal registers are out of reset (if no LTC faults are detected the device status depends on VR1_EN/VR2_EN status). 4. VCC_ov_th ≤ VCC VCC is in overvoltage and SAFE_HIZ is established. The internal supply and reference voltage/currents are available and possibly degraded. Internal registers are out of reset. 1. Indicative value. Not covered by production test or guaranteed by design. In operative conditions VCC is supposed to be within the operating range or at 0 V; values in between are supposed to be applied only during power-up/down transients for an interval based on VCC slew rate requirements. STPM098C Functional description DS14440 - Rev 1 page 12/110 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |