| 数据搜索系统,热门电子元器件搜索 |
|
STPM098C 数据表(PDF) 17 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
STPM098C 数据表(HTML) 17 Page - STMicroelectronics |
|
17 / 110 page ![]() 3.1.3.1 VREF2 voltage monitor VREF2 voltage level is monitored by means of dedicated UV and OV diagnosis. Hysteresis on thresholds and filtering time are implemented. If VREF2 ≤ VREF2_uv_th occurs for an interval longer than T_vref2_uv_flt, VREF2_UV flag is set and SAFE_HIZ is established. The error flag remains set until the failure condition is removed and a rising edge on VR1_EN or VR2_EN is detected. If analog input buffers are available, the failure condition can be removed by PMBus™ command CLEAR_FAULTS or by dedicated commands. If VREF1 ≥ VREF2_ov_th occurs for an interval longer than T_vref2_ov_flt VREF2_OV flag is set and SAFE_HIZ is established. The error flag remains set until the failure condition is removed and a rising edge on VR1_EN or VR2_EN is detected. If analog input buffers are available, the failure condition can be removed by PMBUS command CLEAR_FAULTS or by dedicated commands. VREF2 monitor is safety relevant, then a self-check procedure is implemented. Table 12. VREF2 monitor electrical characteristics Symbol Parameter Test condition Min Typ Max Unit Notes VREF2_uv_th VREF2 undervoltage threshold 2.5 2.7 2.8 V Comparator output low to high VREF2_uv_hys VREF2 undervoltage hysteresis 30 75 120 mV - VREF2_ov_th VREF2 overvoltage threshold 3.6 3.8 4 V Comparator output low to high VREF2_ov_hys VREF2 overvoltage hysteresis 90 160 230 mV - T_vref2_uv_flt VREF2 undervoltage detection filter time CLK_SSM_EN = 0 9 10 11 μs Digital filter T_vref2_ov_flt VREF2 overvoltage detection filter time CLK_SSM_EN = 0 9 10 11 μs Digital filter Figure 11. Power supply operative range t VREF2 VREF2_OV (Internal signal) VREF2_UV (Internal signal) OV VREF2_OV_TH TVREF2_UV_flt UV UV OPERATIVE OPERATIVE VREF2_UV_TH VREF2_OV_HYS VREF2_UV_HYS TVREF2_UV_flt TVREF2_OV_flt TVREF2_OV_flt Note: 1. VREF2 ≤ VREF2_uv_th (max) + VREF2_uv_hyst (max) VREF2 is in undervoltage and SAFE_HIZ is established. 2. VREF2_uv_th ≤ VREF2 ≤ VREF2_ov_th If no other LTC faults are detected the device mode depends on VR1_EN/VR2_EN status. 3. VREF2_ov_th ≤ VREF2 VREF2 is in overvoltage and SAFE_HIZ is established. STPM098C Functional description DS14440 - Rev 1 page 17/110 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |