Back Button SH7708 Datasheet HTML 399Page - Renesas Technology Corp SH7708 Datasheet HTML 400Page - Renesas Technology Corp SH7708 Datasheet HTML 401Page - Renesas Technology Corp SH7708 Datasheet HTML 402Page - Renesas Technology Corp SH7708 Datasheet HTML 403Page - Renesas Technology Corp SH7708 Datasheet HTML 404Page - Renesas Technology Corp SH7708 Datasheet HTML 405Page - Renesas Technology Corp SH7708 Datasheet HTML 406Page - Renesas Technology Corp SH7708 Datasheet HTML 407Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 403 / 633 page
background image
385
character units, so a 16 pulse synchronization clock is output. To receive in 1-character units,
select an external clock source.
Transmitting and Receiving Data: SCI Initialization (synchronous mode). Before transmitting,
receiving, or changing the mode or communication format, the software must clear the TE and RE
bits to 0 in the serial control register (SCSCR), then initialize the SCI. Clearing TE to 0 sets TDRE
to 1 and initializes the transmit shift register (SCTSR). Clearing RE to 0, however, does not
initialize the RDRF, PER, FER, and ORER flags and receive data register (SCRDR), which retain
their previous contents.
Figure 13.15 is a sample flowchart for initializing the SCI. The procedure for initializing the SCI
is:
1. Select the clock source in the serial control register (SCSCR). Leave RIE, TIE, TEIE, MPIE,
TE and RE cleared to 0.
2. Select the communication format in the serial mode register (SCSMR).
3. Write the value corresponding to the bit rate in the bit rate register (SCBRR) unless an external
clock is used.
4. Wait for at least the interval required to transmit or receive one bit, then set TE or RE in the
serial control register (SCSCR) to 1. Also set RIE, TIE, TEIE and MPIE. Setting TE and RE
allows use of the TxD and RxD pins.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com