12 / 114 page ![]() SIMOCODE 3UF Motor Management and Control Devices SIMOCODE pro 3UF7 motor management and control devices 7/12 Siemens LV 1 T · 2006 Monitoring additional process variables over analog inputs (0/4 ... 20 mA)1)2) • The analog module enables SIMOCODE pro to measure additional process variables and monitor them. A pump can, for example, be protected against dry running in this manner with level monitoring or the degree of pollution of a filter can be measured using a differential pressure transducer. When a specified level is undershot, the pump can be deactivated and when a specified differential pressure is overshot, the filter can be cleaned. • SIMOCODE pro supports two-step monitoring of the corre- sponding process variable for freely selectable upper and lower current limit values. The response of SIMOCODE pro can be freely configured and delayed if it reaches an alarm or tripping threshold. Phase sequence detection3) • By detecting the phase sequence, SIMOCODE pro is able to make a statement about the direction of rotation of a motor. If the direction is incorrect, this can be reported or it can result in immediate shutdown of the affected motor. Monitoring of operating hours, downtime and number of starts • In order to prevent plant downtime caused by motor failure due to excessive motor operating times (wear) or excessive motor downtimes, SIMOCODE pro can monitor the operating hours and downtime of a motor. When an adjustable limit value is violated, a message or alarm can be generated which can indicate that the corresponding motor must be serviced or replaced. After the motor has been replaced, the operating hours and downtimes can be reset, for example. • To avoid excessive thermal loads and early wear of the motor, it is possible to limit the number of motor startups for a specifiable period. Alarms can indicate that only a small number of possible starts remain. Flexible motor control implemented with software Many typical motor control functions have been predefined in SIMOCODE pro and are available for use: • Direct-on-line and reversing starters • Wye-delta starters (also with direction reversal)1) • Two speeds, motors with separate windings (pole-changing switch); also with direction reversal1) • Two speeds, motors with separate Dahlander windings (also with direction reversal)1) • Slide control1) • Solenoid valve actuation1) • Actuation of a circuit-breaker (MCCB) • Actuation of a 3RW soft starter also with direction reversal1) These control programs already include all the software interlocks and logic operations required for operation of the required motor functions. It is also monitored whether the current checkback of the motor feeder corresponds with the control command. If not, SIMOCODE pro opens the motor contactor and generates an alarm indication. Depending on the application, motor control can be switched over or carried out simultaneously from several control stations, e.g.: • From the I&C system through PROFIBUS DP • From a PC/PG through PROFIBUS DP • From the control cabinet door through the operator panel • From a PC/PG on the system interface through SIMOCODE pro • From a local control station on the motor. In this case, the buttons, switches and indicator lights are connected to the inputs and outputs of SIMOCODE pro. Regardless of whether a control command is sent to SIMOCODE pro via PROFIBUS DP using the operator module or via the buttons connected to the binary SIMOCODE pro inputs, SIMOCODE pro can execute these control commands simultaneously or in accordance with the enabled commands defined during configuration. These predefined control functions can also be flexibly adapted to each customized configuration of a motor feeder by means of freely configurable logic modules (truth tables, counters, timers, edge evaluation etc.). In addition, special standard functions are stored in SIMOCODE pro which can also be used to extend the protection and control functions, e.g.: • Power failure monitoring1) for automatic, time-staggered restart of motors following a network failure e.g. with the help of a separate voltage relay (voltage controller). • Fault signaling modules for external faults with or without manual or automatic acknowledgement for generating internal messages or for tripping SIMOCODE pro in response to freely definable events (e.g. overspeed monitor has been activated). Designations/names can also be assigned to the external faults which are stored in the device and which are therefore also available to the I&C system. • Emergency start function and reset of the thermal memory of SIMOCODE pro after tripping, i.e. immediate restart is possible (important, for example, for pumps used to extinguish fires). • Test function for the load feeder circuit when the main control switch is open to test the control circuit while the main circuit is de-energized. Detailed operational, service and diagnostics data SIMOCODE pro provides a variety of operating, service and diagnostic data, such as: Operating data • The switching state of the motor (On, Off, clockwise, counter- clockwise, fast, slow) is derived from the current flow in the main circuit, so checkbacks are not required through auxiliary contacts from circuit-breakers and contactors • Current in phase 1, 2, 3 and maximum current in % of the set current • Voltage in phases 1, 2, 3 in V3) • Active power in W3) •Apparent power in VA3) • Power factor in %3) • Phase unbalance in % • Phase sequence3) • Temperature in sensor circuits 1, 2, 3 and maximum temperature in °C1)4) • Current values of the analog signals1)2) • Time until tripping in sec. • Temperature rise for motor model in % • Remaining cooling time of the motor in sec. etc. Service data • Motor operating hours (can be reset) • Motor stop times (can be reset) • Number of motor starts (can be reset) • Number of remaining permissible motor starts • Number of overload trips (can be reset) • Internal comments, stored in the device for each feeder, e.g. notes for maintenance events etc. 1) Using basic unit 2. 2) An additional analog module is required. 3) Using basic unit 2 with current/voltage measuring module. 4) An additional temperature module is required. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |