16 / 114 page ![]() SIMOCODE 3UF Motor Management and Control Devices SIMOCODE pro 3UF7 motor management and control devices 7/16 Siemens LV 1 T · 2006 1) Screw connection is possible using a suitable 3RT19 ... box terminal. 2) When connecting cable lugs acc. to DIN 46235, use the 3RT19 56-4EA1 terminal cover for conductor cross-sections from 95 mm2 to ensure phase spacing. 3) When connecting cable lugs acc. to DIN 46234 for conductor cross- sections from 240 mm2 as well as DIN 46235 for conductor cross-sections from 185 mm2, use the 3RT19 66-4EA1 terminal cover to ensure phase spacing. Current measuring modules or current/voltage measuring modules Connection for main circuit Feed-through opening (diameter) • Set current Ie = 0.3 ... 3 A; 2.4 ... 25 A mm 7.5 • Set current Ie = 10 ... 100 A mm 14.0 • Set current Ie = 20 ... 200 A mm 25.0 Busbar connection1) • Set current Ie A 20 ... 200 63 ... 630 • Terminal screw M8 x 25 M10 x 30 • Tightening torque Nm 10 ... 14 14 ... 24 • Solid with cable lug mm2 16 ... 952) 50 ... 2403) • Stranded with cable lug mm2 25 ... 1202) 70 ... 2403) • AWG cable AWG 6... 3/0kcmil 1/0 ... 500 kcmil Conductor cross-sections for voltage measurement • Tightening torque Nm 0.8 ... 1.2 • Solid mm2 1 x (0.5 ... 4.0); 2 x (0.5 ... 2.5) • Finely stranded with end sleeve mm2 1 x (0.5 ... 2.5); 2 x (0.5 ... 1.5) • AWG cable (solid) AWG 1xAWG20to12/2xAWG20to14 • AWG cable (finely stranded) AWG 1xAWG20to14/2xAWG20to16 Digital modules Mounting Snap-on mounting onto 35 mm standard mounting rail or screw fixing with additional push-in lugs Displays • Green LED "READY" Continuous light: "Ready" Flashing: "No connection to the PC" System interfaces for connecting to a basic unit, another expansion module, a current measuring module or current/voltage measuring module or to the operator panel Control circuit Rated insulation voltage Ui V 300 (at pollution degree 3) Rated impulse withstand voltage Uimp kV 4 Relay outputs •Number 2 monostable or bistable relay outputs (depending on the variant) • Auxiliary contacts of the 2 relay outputs Floating NO contact (NC contact response can be parameterized with internal signal conditioning), all relay outputs are jointly connected to a common potential, they can be freely assigned to the control functions (e.g. for line, wye and delta contactors and for signaling the operating status) • Specified short-circuit protection for auxiliary contacts (relay outputs) • Fuse links, operational class gL/gG 6 A, quick 10 A (IEC 60947-5-1) • Miniature circuit-breaker 1.6 A, C characteristic (IEC 60947-5-1) • Miniature circuit-breaker 6 A, C characteristic (Ik<500 A) • Rated uninterrupted current A 6 • Rated short-circuit capacity AC-15 6 A/24 V AC 6 A/120 V AC 3 A/230 V AC DC-13 2 A/24 V DC 0.55 A/60 V DC 0.25 A/125 V DC Inputs (binary) 4 externally supplied floating inputs, 24 V DC or 110 to 240 V AC/DC depending on the variant; inputs jointly connected to common potential for sensing process signals (e.g.: local control station, key switch, limit switch ...), freely assignable to the control functions Conductor cross-sections • Tightening torque Nm 0.8 ... 1.2 • Solid mm2 1 × (0.5 ... 4.0); 2 × (0.5 ... 2.5) • Finely stranded with end sleeve mm2 1 × (0.5 ... 2.5); 2 × (0.5 ... 1.5) • AWG cable (solid) AWG 1xAWG20to12/2xAWG20to14 • AWG cable (finely stranded) AWG 1xAWG20to14/2xAWG20to16 Ground fault modules Mounting Snap-on mounting onto 35 mm standard mounting rail or screw fixing with additional push-in lugs Displays • Green LED "READY" Continuous light: "Ready" Flashing: "No connection to the PC" System interfaces for connecting to a basic unit, another expansion module, a current measuring module or current/voltage measuring module or to the operator panel Control circuit Connectable 3UL22 summation current transformer with rated fault currents IN A 0.3/0.5/1 • IGround fault 50 % IN No tripping • IGround fault 100 % IN Tripping Response delay ms 300 ... 500, additionally delayable Conductor cross-sections • Tightening torque Nm 0.8 ... 1.2 • Solid mm2 1 × (0.5 ... 4.0); 2 × (0.5 ... 2.5) • Finely stranded with end sleeve mm2 1 × (0.5 ... 2.5); 2 × (0.5 ... 1.5) • AWG cable (solid) AWG 1xAWG20to12/2xAWG20to14 • AWG cable (finely stranded) AWG 1xAWG20to14/2xAWG20to16 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |