65 / 114 page ![]() Monitoring Relays 7/65 Siemens LV 1 T · 2006 3UG Monitoring Relays for Electrical and Additional Measurements Line monitoring 3UG46 15/3UG46 16 monitoring relays The 3UG46 15/3UG46 16 line monitoring relay has a wide voltage range and an internal power supply. The device is equipped with a display and is parameterized using three buttons. The 3UG46 15 device monitors three-phase networks with regard to phase failure, undervoltage, overvoltage and phase sequence. The 3UG46 16 monitoring relay monitors the neutral conductor as well. The hysteresis is adjustable from 1 to 20 V. In addition the device has two separately adjustable delay times for overvoltage and undervoltage from 0 to 20 s in each case. If the direction is incorrect, the device switches off immediately. Thanks to a special measuring method, a phase failure is reliably detected in spite of the wide voltage range from 160 to 690 V AC and feedback through the load of up to 80 %. The 3UG46 15/3UG46 16 monitoring relay can be operated on the basis of either the open-circuit or closed-circuit principle and with manual or auto RESET. With the closed-circuit principle selected Wrong phase sequence Phase failure Undervoltage Overvoltage 3UG46 17/3UG46 18 monitoring relays The 3UG46 17/ 3UG46 18 line monitoring relay has an internal power supply and can automatically correct a wrong direction of rotation. Thanks to a special measuring method, a phase failure is reliably detected in spite of the wide voltage range from 160 to 690 V AC and feedback through the load of up to 80 %. The device is equipped with a display and is parameterized using three buttons. The 3UG46 17 line monitoring relay monitors three-phase networks with regard to phase sequence, phase failure, phase unbalance, undervoltage and overvoltage. The 3UG46 18 monitoring relay monitors the neutral conductor as well. The hysteresis is adjustable from 1 to 20 V. In addition the device has delay times from 0 to 20 s in each case. The times respond to overvoltage, undervoltage, phase failure and phase unbalance. The 3UG46 17/3UG46 18 monitoring relay can be operated on the basis of either the open-circuit or closed-circuit principle and with manual or auto RESET. The one changeover contact is used for warning or switching off in the event of line faults (voltage, unbalance), the other responds only to a wrong phase sequence. In conjunction with a contactor reversing assembly it is thus possible to change the direction automatically. With the closed-circuit principle selected Phase failure Undervoltage Overvoltage Unbalance 11/14 L3-L2-L1 11/12 21/24 21/22 11/14 11/12 21/24 21/22 L1-L2-L3 L1-L2-L3-N L2-L3 L1-L2-L3 L1-L2-L3 L1-L2-L3-N < 21/24 21/22 11/14 11/12 x-y Hysteresis Delay > x-y 21/24 21/22 11/14 11/12 Hysteresis Delay 11/14 50 ms 11/12 21/24 21/22 L1-L2-L3 L1-L2-L3-N L2-L3 L1-L2-L3 L1-L2-L3 L1-L2-L3-N 11/14 50 ms 11/12 21/24 21/22 < x-y Hysteresis Delay 11/14 50 ms 11/12 21/24 21/22 > x-y Hysteresis Delay 11/14 50 ms 11/12 21/24 21/22 > Asy 0 % Hysteresis 2 % Delay |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |