80 / 114 page ![]() Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Insulation monitoring for ungrounded DC networks 7/80 Siemens LV 1 T · 2006 ■Overview Relay for monitoring the insulation resistance between ungrounded pure DC networks and a protective-ground conductor: • Measuring principle for differential current measurement • Response threshold can be set continuously from 10 to 110 k W • Selectable - Auto reset function with hysteresis or - Storage of the tripping operation • Front selector switch for open-circuit and closed-circuit principle for the output relay • Test function with test buttons on the front for L+ and L- and over terminal connections • Switching output: 1 CO contact • Insulation fault indicator for L+ and L- through two red LEDs • Supply voltage indication with a green LED • Electro-magnetically compatible according to EN 50081 and EN 61000-6-2 ■Function The monitoring relay measures the insulation voltage between the positive and negative supply voltage in an ungrounded DC network and a corresponding protective conductor. The measurement is based on the DC residual current measurement principle. The response value can be adjusted steplessly in the range from 10 to 110 k W and thus can be adapted to the corresponding conditions. If the insulation resistance falls below the set response value, the output relay triggers (depending on the setting of the open/closed-circuit principle selector switch) and a fault LED lights up. A ground fault is evaluated separately for L+ and L- and indicated by means of a corresponding LED. Note: Due to the measurement principle, a symmetrical ground fault on terminals L+ and L- cannot be evaluated. Test function A ground fault can be simulated using the Test L+ and Test L- buttons on the front. If the test button is pressed for at least 1 s, the status of the output relay changes and the corresponding fault LED lights up. An external test button can be connected to terminals Y1-Y3 for L+ and terminals Y4-Y3 for L-. The function is triggered by means of a NO contact. Fault storage and RESET If terminals Y2 and Y3 are linked, the monitoring relay is set to fault storage mode. If the insulation resistance falls below the set value, the output relay triggers (depending on the setting of the open/closed circuit selector switch), and stays in this state even if the insulation resistance rises again above the hysteresis value (typical: 2 times the set value). This fault storage can be deleted by pressing and releasing the L+ RESET button, opening the Y2-Y3 connection or by switching off the supply voltage. Open/closed-circuit principle selector switch The function principle of the output relay can be adjusted by means of a selector switch on the front panel. If the relay is to respond in the event of a fault (contact symbol open), the open-circuit principle must be selected. If the relay however is to trigger in the event of a fault (contact symbol closed), the closed-circuit principle must be selected. Note: The position of the selector switch has no effect upon the fault LEDs. The LEDs always light up if the insulation resistance on L+ or L– falls below the set value. A 1 / A 2 Y 3 / Y 4 1 1 / 1 4 1 1 / 1 2 R N S B 0 _ 0 1 3 9 5 R v a l u e Y 1 / Y 3 Y 2 / Y 3 L + / P E L - / P E 1 2 3 4 5 6 7 8 T e s t > s 1 2 3 4 5 6 7 8 R T e s t H y s t x R H y s t O p e n - c i r c u i t / c l o s e d - c i r c u i t p r i n c i p l e = a p p r o x . 1 s = t y p i c a l l y 2 x R = S u p p l y v o l t a g e = B u t t o n o n f r o n t - R e s e t L + a n d L - / T e s t L + = B u t t o n o n f r o n t - T e s t L - T e s t r e m o t e c o n n e c t i o n - T e s t L - = T e s t r e m o t e c o n n e c t i o n - T e s t L + = T e s t r e m o t e c o n n e c t i o n - S t o r e , r e s e t = I n s u l a t i o n r e s i s t a n c e R o f s u p p l y s e t r e s p o n s e v a l u e R = S w i t c h o n f r o n t O p e n - c i r c u i t / c l o s e d - c i r c u i t p r i n c i p l e = N O c o n t a c t |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |