85 / 114 page ![]() Monitoring Relays 7/85 Siemens LV 1 T · 2006 3UG Monitoring Relays for Electrical and Additional Measurements Speed monitoring ■Overview The 3UG30 51 monitoring relay is used together with a sensor to monitor drives for underspeeding. ■Function The underspeed monitoring relay operates according to the principle of retriggerable OFF-delay. During the time (value) set on the front panel, another pulse must arrive at input IN1 or IN2 to ensure that the output relay remains picked up. The monitoring relay evaluates the rising edge of the signal, i.e. a continuous signal is also recognized as a missing pulse. If the retrigger pulse does not arrive, indicating a reduction in speed, the output relay drops. In order to be able to start a drive, the output relay remains picked up during the ON-delay time T, even if the speed is still below the set value (motor starting override time). The first pulse must come within this time. The monitoring relay can be used for all functions where a continuous pulse signal needs to be monitored (belt travel monitoring, completeness monitoring, passing monitoring, clock-time monitoring). Speed monitoring without memory (NO MEMORY) When the speed of the drive drops below the set value, the output relay drops. It picks up again when the speed is greater than the set value plus the fixed hysteresis. Speed monitoring with memory (MEMORY) When the output relay drops, this state remains stored even when the speed reaches a permissible value again. The stored state can be ended by a control signal at the reset terminal or by interrupting the supply voltage for at least 200 ms. ■Technical specifications 1) Short-circuits without any contact welding acc. to DIN VDE 0660 Part 200. N S B 0 _ 0 0 9 6 5 A 1 / A 2 T 1 2 4 3 1 2 3 4 S e t v a l u e H y s t e r e s i s A c t u a l v a l u e O u t p u t r e l a y N S B 0 _ 0 0 9 6 6 A 1 / A 2 T T 5 2 1 4 3 6 6 1 2 3 4 6 5 S e t v a l u e H y s t e r e s i s A c t u a l v a l u e O u t p u t r e l a y R e s e t S t o r a g e ( M E M O R Y ) Type 3UG30/3UG35 Load capacity of the output relay Rated operational current Ie A max. 8 AC-15/230 V A 3 DC-13/24 V A 1 DC-13/48 V A 0.45 DC-13/60 V A 0.35 DC-13/110 V A 0.2 DC-13/230 V A 0.1 Minimum contact load mA 5/17 V for a fault of 1 ppm Output relay with DIAZED fuse1) gl/Gg operational class A 4 Electrical endurance Operating cycles 1 x 105 Mechanical endurance Operating cycles 2 x 106 Ambient temperature During operation °C -20 ... + 50 During storage °C -30 ... + 70 Connection of conductors Solid mm² 2 x (0.5 ... 2.5) Finely stranded, with end sleeves mm² 2 x (0.5 ... 1.5) Degree of protection Terminals IP20 Enclosures IP40 Vibration resistance acc. to IEC 60068-2-6 Hz/mm 10 ... 150/0.035 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |