78 / 114 page ![]() Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Insulation monitoring for ungrounded AC networks 7/78 Siemens LV 1 T · 2006 ■Overview Relay for monitoring the insulation resistance between the ungrounded single or three-phase AC supply and a protective ground conductor: • Measuring principle with superimposed DC voltage • Two selectable measuring ranges of 1 ... 110 k W • Stepless setting within the measuring range • Selectable: - Auto reset function with fixed hysteresis or - Storage of the tripping operation • Test function with test button and terminal connections on the front • Switching output: 1 CO contact • Insulation fault indication with a red LED • Supply voltage indication with a green LED • Electro-magnetically compatible according to EN 50081 and EN 61000-6-2. ■Function The monitoring relay measures the insulation resistance between the ungrounded AC supply and an associated protective ground conductor. A superposed DC measuring voltage is used to perform the measurement. The monitoring relay is divided into two ranges for an insulation resistance range from 1 to 100 k W. A range switch on the front can be used to switch over between a 1 to 11 k W range and a 10 to 110 k W range. Within the selected range, the monitoring relay can be steplessly adapted to the respective insulation conditions. If the insulation resistance undershoots the set threshold, the output relay is excited and the red LED (fault display) is lit. If the insulation resistance exceeds 1.6 times (corresponding to 60 % hysteresis) the set threshold, the output relay will return to the rest position. Test functions The "Test" button on the front can be used to simulate a ground fault. If the "Test" button is pressed for at least 300 ms, the output relay is energized and the fault LED lights up. An external test button can be connected to terminal Y1. The function is activated by closing (> 300 ms). Fault storage and RESET If terminals Y1 and Y2 are jumpered, the monitoring relay is set to fault storage mode. If the set insulation resistance is under- shot, the output relay is excited and remains tripped even after the insulation resistance rises above 1.6 times the set value again. Fault storage can be reset by briefly pressing the RESET button, briefly jumpering (< 300 ms) the Y1 and PE/ground terminals or by switching off and on the supply voltage. Note: The monitoring relay is designed for AC supply systems. Series-connected rectifiers must be galvanically isolated from the measuring relay that is to be monitored. A1/A2 A1/B2 Y1/Y2 Y1/PE 11/14 11/12 1 2 3 R 4 5 value Rvalue Test NSB0_01393 Test 1 2 3 4 5 = > approx. 300 ms = Supply voltage A1-B2/A1-A2 for 115 V/230 V AC A1-A2 for 24 ... 240 V AC/DC = Remote connection- save-reset = Key on the front - test/reset = Insulation resistance R of network Set operating value R = NO contact 1.6 x R |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |