| 数据搜索系统,热门电子元器件搜索 |
|
3UG3501 数据表(PDF) 71 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
3UG3501 数据表(HTML) 71 Page - List of Unclassifed Manufacturers |
|
71 / 114 page ![]() Monitoring Relays 7/71 Siemens LV 1 T · 2006 3UG Monitoring Relays for Electrical and Additional Measurements Voltage monitoring ■Technical specifications 1) Note: This is a Class A product. In the household environment this device may cause radio interference. In this case the user must introduce suitable measures. 3UG46 31- .AA 3UG46 31- .AW 3UG46 32- .AA 3UG46 32- .AW 3UG46 33 General data Rated control supply voltage Us V 24 AC/DC 24 ... 240 AC/DC 24 AC/DC 24 ... 240 AC/DC 17 ... 275 AC/DC Rated frequency for AC Hz 50/60 40 ... 500 Operating range V 20.4 ... 27.6 20.4 ... 275 20.4 ... 27.6 20.4 ... 275 17 ... 275 Rated output VA 2/4 Width mm 22.5 RESET Automatic/manual Availability time after application of Us ms 1000 Response time on occurrence of a fault ms 300 Adjustable tripping delay time s 0.1 … 20 Adjustable ON-delay time s -- 0.1 ... 20 Mains buffering time, typical ms 10 Rated insulation voltage Ui Pollution degree 3 Overvoltage category III acc. to VDE 0110 V 300 -- 690 300 Rated impulse withstand voltage Uimp kV 4 6 4 Permissible ambient temperature • During operation °C -25 … +60 • During storage °C -40 … +85 EMC tests1) IEC 60947-1/IEC 61000-6-2/IEC 61000-6-4 Degree of protection • Enclosures IP40 • Terminals IP20 Vibration resistance acc. to IEC 60068-2-6 Hz/mm 1-6/1S; 6-500, 20 m/s2 Shock resistance acc. to IEC 60068 Part 2-27 g/ms 15/11 Conductor cross-section • Screw-type connection M 3 (standard screwdriver size 2 and Pozidriv 2) -Solid mm2 1 x (0.5 ... 4)/2 x (0.5 ... 2.5) - Finely stranded with end sleeve mm2 1 x (0.5 ... 2.5)/2 x (0.5 ... 1.5) - AWG conductors, solid or stranded AWG 2 x (20 ... 14) - Tightening torque Nm 0.8 … 1.2 • Spring-loaded terminals -Solid mm2 2 x (0.25 ... 1.5) - Finely stranded, with end sleeves acc. to DIN 46228 mm2 2 x (0.25 ... 1.5) - Finely stranded mm2 2 x (0.25 ... 1.5) - AWG conductors, solid or stranded AWG 2 x (24 ... 16) Measuring circuits Permissible measuring range single-phase AC/DC voltage V 0.1 ... 90 10 ... 650 17 ... 275 Setting range single-phase voltage V 0.1 ... 60 10 ... 600 17 ... 275 Measuring frequency Hz 40 ... 500 40 ... 500 Measuring accuracy % 5 Repeat accuracy at constant parameters % 1 Accuracy of digital display 1 digit Deviations for temperature fluctuations %/°C 1 Hysteresis for single-phase voltage V 0.1 ... 30 0.1 ... 300 0.1 ... 150 Control circuits Load capacity of the output relay • Thermal current limit Ith A 5 Rated operational current Ie at • AC-15 230/400 V A 3 • DC-13 24 V A 1 • DC-13 110 V A 0.2 • DC-13 230 V A 0.1 Minimum contact load at 17 V DC mA 5 Output relay with DIAZED fuse gl/Gg operational class A 4 Electrical endurance AC-15 Million operating cycles 0.1 Endurance with contactor relay Million operating cycles 10 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |