| 数据搜索系统,热门电子元器件搜索 |
|
3UG3501 数据表(PDF) 64 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
3UG3501 数据表(HTML) 64 Page - List of Unclassifed Manufacturers |
|
64 / 114 page ![]() Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Line monitoring 7/64 Siemens LV 1 T · 2006 3UG45 13 monitoring relays The 3UG45 13 line monitoring relay monitors three-phase networks with regard to phase sequence, phase failure, phase unbalance of 20 % and undervoltage. The device has an internal power supply and works using the closed-circuit principle. The hysteresis is 5 %. The integrated response delay time is adjustable from 0 to 20 s and responds to undervoltage. If the direction is incorrect, the device switches off immediately. Thanks to a special measuring method, a phase failure is reliably detected in spite of the wide voltage range from 160 to 690 V AC and feedback through the load of up to 80 %. When the mains supply is switched on, the green LED is lit. If the phase sequence at the terminals L1-L2-L3 is correct, the output relay picks up. If the phase sequence is wrong, the red LED flashes and the output relay remains in its rest position. If a phase fails, the red LED is permanently lit and the output relay drops. Note: The red LED is a fault diagnostic indicator and does not show the current relay status. The 3UG45 13 monitoring relay is suitable for line frequencies of 50/60 Hz. Phase failure and undervoltage Wrong phase sequence 3UG46 14 monitoring relays The 3UG46 14 line monitoring relay has a wide voltage range and an internal power supply. The device is equipped with a display and is parameterized using three buttons. It monitors three-phase networks with regard to phase unbalance from 5 to 20 %, phase failure, undervoltage and phase sequence. The hysteresis is adjustable from 1 to 20 V. In addition, the device has a response delay and ON delay from 0 to 20 s in each case. The integrated response delay time responds to phase unbalance and undervoltage. If the direction is incorrect, the device switches off immediately. Thanks to a special measuring method, a phase failure is reliably detected in spite of the wide voltage range from 160 to 690 V AC and feedback through the load. The 3UG46 14 monitoring relay can be operated on the basis of either the open-circuit or closed-circuit principle and with manual or auto RESET. With the closed-circuit principle selected Wrong phase sequence Phase failure Undervoltage Unbalance NSB0_01569 11/14 -20% L1-L2-L3 L2-L3 L1-L2-L3 n 3~U 5% 11/12 21/24 21/22 LED rd Delay OFF OFF OFF Hysteresis ON Phase loss ON 11/14 L3-L2-L1 11/12 21/24 21/22 LED rd FLASH Phase sequence OFF OFF 11/14 L3-L2-L1 11/12 21/24 21/22 11/14 11/12 21/24 21/22 L1-L2-L3 L2-L3 L1-L2-L3 < 21/24 21/22 11/14 11/12 x-y Hysteresis Delay onDelay > Asy 0% 21/24 21/22 11/14 11/12 Hysteresis 2% Delay onDelay |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |