98 / 114 page ![]() Monitoring Relays 3RN1 Thermistor Motor Protection For PTC sensors 7/98 Siemens LV 1 T · 2006 3RN10 62 tripping units for multiple motor protection Up to 6 sensor circuits can be connected to the 3RN10 62 tripping unit, all of which act on one output relay. The simultaneous protection of several motors (up to 6) is an advantage for multi-motor drives (e.g. if one motor is overloaded, all the other motors of the drive will be shut down). Apart from the red LED TRIPPED, which signals the switching status of the tripping unit, an LED is assigned to each sensor circuit which indicates the sensor circuit that has responded. Unused sensor circuits must be short-circuited. The reset response of the 3RN10 62 tripping units can be changed from manual RESET to automatic RESET by linking terminals Y1 and Y2. Remote RESET is implemented by connecting an external pushbutton with a normally-open function. Response of the tripping units in the event of control voltage failure Safe electrical isolation All circuits (outputs, control circuits, sensor and RESET circuits) of the multifunction tripping units 3RN10 13-1BW10 and 3RN10 13-1GW10 (wide voltage range, monostable output relay and screw-type terminals) are safely isolated from each other up to a rated voltage of 300 V according to DIN VDE 0100 Part 410/EN 60947-1. Function diagrams 3RN10 00/3RN10 10 (Auto-RESET) 3RN10 111) 3RN10 13-...01 3RN10 121)/3RN10 22/3RN10 62 3RN10 13-...0 3RN10 22 only 1) For versions with 2 CO (3RN10 1.G...): See 3RN10 13. function diagram for short-circuit response of sensor circuit. Behavior for Monostable Non-volatile Monostable Bistable 3RN10 00 3RN10 10 3RN10 11 3RN10 12 3RN10 13-...0 3RN10 22 3RN10 62 3RN10 13-...01 Failure of the control voltage Device trips Device trips No change in state of the auxiliary contacts Return of the control voltage without a preceding tripping operation Device resets Device resets No change in state of the auxiliary contacts Return of the control voltage after a preceding tripping operation Device resets The device remains tripped No change in state of the auxiliary contacts A1/A2 T1/T2 LED Tripped NSB0_00314b 3800 1500 K A 1 / A 2 T 1 / T 2 ( Y 1 / Y 2 ) N S B 0 _ 0 0 3 1 5 c 3 8 0 0 1 5 0 0 K L E D T r i p p e d A1/A2 3800 T1/T2 RESET (Y1/Y2) NSB0_00316a 1500 K LED Tripped A1/A2 T1/T2 RESET (Y1/Y2) NSB0_00317a 3800 1500 K, K2 LED Tripped A1/A2 T1/T2 RESET (Y1/Y2) NSB0_00318a 3800 1500 K LED Tripped 2T1/T2 LED Alarm NSB0_00319b 3800 1500 K1 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |