| 数据搜索系统,热门电子元器件搜索 |
|
3UG3501 数据表(PDF) 28 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
3UG3501 数据表(HTML) 28 Page - List of Unclassifed Manufacturers |
|
28 / 114 page ![]() SIMOCODE 3UF Motor Management and Control Devices SIMOCODE-DP 3UF5 motor protection and control devices 7/28 Siemens LV 1 T · 2006 • Two speeds, Dahlander winding • Two speeds, separate winding •Valve • Actuator • Soft starter (3RW) These control programs already include all the software interlocks and logic operations required for operation of the required motor functions. It is also monitored whether the current checkback of the motor feeder corresponds with the control command. If not, SIMOCODE-DP opens the motor contactor and generates an alarm indication. The motor can be controlled by any equipment depending on the application: • From the process control system or the PC through PROFIBUS DP • From the control cabinet door through the operator panel • From a local control point on the motor, whereby the pushbuttons/switches are wired to the SIMOCODE-DP inputs The standard control functions can also be adapted to each customized variant of a motor feeder by means of freely- parameterizable elements, such as timers, counters, logic operations (AND, OR, NOR, etc.). Furthermore, special standard function blocks are stored in SIMOCODE-DP: • Automatic, time-discrete reactivation of motors following mains failure The prerequisites are as follows: - Failure of the three-phase supply must take place through a separate voltage relay - The supply voltage of SIMOCODE-DP must not be interrupted • Different error signaling modules with and without acknowledgement These allow SIMOCODE-DP to trip as a result of external events (e.g. overspeed monitor has tripped) • The emergency start function This resets the thermal memory of SIMOCODE-DP immediately after overload tripping, i.e. immediate restarting is possible (important, for example, for a fire-extinguisher pump) • The test function for the load feeder This can be activated by switching off the main switch Q1 (see the section Schematics) and allows the control circuit to be checked with the motor branch at zero current. ■Integration The SIMOCODE-DP modular system offers a wide range of software packages for system-wide and time-saving configuration and diagnostics: • PC software Win-SIMOCODE-DP for start-up and service • Object manager OM-SIMOCODE for "totally integrated" in SIMATIC S7 • Function block FB-SIMOCODE for "totally integrated" in PCS7 PC software Win-SIMOCODE-DP for start-up and service Standard PC software Win-SIMOCODE-DP for start-up and service. It offers a user-friendly and convenient user-interface for: • Parameterization • Display and diagnostics • Test functions • Motor control Win-SIMOCODE-DP is available in two versions: • Win-SIMOCODE-DP/Smart for direct connection to SIMOCODE-DP through the system interface on the device • Win-SIMOCODE-DP/Professional for direct connection to SIMOCODE-DP over PROFIBUS or directly through the system interface on the device OM-SIMOCODE object manager for "totally integrated" in SIMATIC S7 SIMOCODE-DP can be integrated into SIMATIC S7 in two different ways: • Conventionally using GSD files i.e. integration in SIMATIC S7 is identical to integration in any other DP standard master system • Using the OM-SIMOCODE-DP object manager i.e. SIMOCODE-DP becomes an integral component of STEP 7; the OM-SIMOCODE-DP object manager should, in this case, always be combined with the start-up and service software Win-SIMOCODE-DP/Professional Both software packages must be installed on the PG/PC on which the hardware configuration of SIMATIC S7 is performed. This ensures that Win-SIMOCODE-DP/Professional can be called up directly from HW-Config. Parameter sets created with Win-SIMOCODE-DP/Professional are loaded into the STEP 7 data storage by means of OM and automatically transferred to SIMOCODE-DP during start-up. Functions specific to SIMATIC S7, such as diagnostic and hardware interrupts are supported, which means easier S7-wide configuration as well as optimal performance in the transfer of diagnostic data. Function block FB-SIMOCODE for "totally integrated" in PCS7 With PCS7-FB SIMOCODE-DP it is easy and convenient to integrate SIMOCODE-DP into the SIMATIC PCS 7 process control system. PCS7-FB SIMOCODE-DP contains the diagnostic and driver blocks corresponding with the diagnostic and driver concept of SIMATIC PCS 7 as well as the elements (symbols and faceplate) required for operator control and process monitoring. The application is integrated by graphic interconnection using the CFC Editor. The technological and signal processing functions of the PCS7-FB SIMOCODE-DP are based on the SIMATIC PCS 7 standard libraries (driver blocks, technological blocks) and are optimally tailored to SIMOCODE- DP. Users who previously configured motor feeder circuits using conventional technology by means of signal blocks and motor or valve blocks, can now easily switch to PCS7-FB SIMOCODE-DP. The PCS7-FB SIMOCODE-DP supplied on CD-ROM allows the user to run the required engineering software on one engineering station (single license) including the runtime software for executing the AS blocks in an automation system (single license). |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |