| 数据搜索系统,热门电子元器件搜索 |
|
3UG3501 数据表(PDF) 60 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
3UG3501 数据表(HTML) 60 Page - List of Unclassifed Manufacturers |
|
60 / 114 page ![]() 3RP, 7PV Timing Relays 3RT19 timing relays for mounting to contactors 7/60 Siemens LV 1 T · 2006 ■Technical specifications According to IEC 61 812-1/DIN VDE 0435 Part 2021 Type 3RT19 16-2C 3RT19 16-2D 3RT19 26-2C 3RT19 26-2D 3RT19 16-2E 3RT19 16-2F 3RT19 16-2G 3RT19 16-2L 3RT19 26-2E 3RT19 26-2F 3RT19 26-2G Rated insulation voltage Pollution degree 3 Overvoltage category III to DIN VDE 0110 V AC 300 Operating range of excitation 0.8...1.1 x Us, 0.95 ... 1.05 times rated frequency 0.85...1.1 x Us, 0.95 ... 1.05 times rated frequency Rated power W 1 2 (1 W for 3RT1916-2L) • Power consumption at 230 V AC, 50 Hz VA 1 4 Rated operational currents Ie • AC-14 and DC-13 A 0.3 for 3RT1916 0.5 for 3RT1926 -- • AC-15 at 230 V AC, 50 Hz A -- 3 • DC-13 at 24 V A -- 1 • DC-13 at 110 V A -- 0.2 • DC-13 at 230 V A -- 0.1 DIAZED fuse gL/gG operational class A -- 4 Switching frequency • When loaded with Ie 230 V AC 1/h 2500 2500 • When loaded with 3RT1016 contactor, 230 V AC 1/h 2500 5000 Recovery time ms 50 150 Minimum ON period ms 35 200 (OFF-delay, without auxiliary voltage) 3RT1916-2L: 35 (OFF-delay, with auxiliary voltage) Residual current (two-wire) mA 5 -- Voltage drop with conducting output VA 3.5 -- Short-time loading capacity A 10 (to 10 ms) -- Setting accuracy with reference to upper limit of scale 15 % Repeat accuracy 1% Mechanical endurance Operating cycles 100 x 106 10 x 106 Permissible ambient temperature During operation °C -25 ... +60 During storage °C -40 ... +85 Degree of protection acc. to EN 60529 IP 40 cover IP 20 terminals Connection of conductors Solid mm² 2 x (0.5 ... 1.5), 2 x (0.75 ... 4) Finely stranded with end sleeve mm² 2 x (0.5 ... 2.5) Solid or stranded AWG 2 x (18 ... 14) Terminal screw M3 Tightening torque Nm 0.8 ... 1.2 Permissible mounting position Any Shock resistance Half sine acc. to IEC 60068-2-27 g/ms 15/11 Vibration resistance acc. to IEC 60068-2-6 Hz/mm 10 ... 55 / 0.35 EMC tests acc. to basic specification IEC 61000-6-2/IEC 61000-6-4 Overvoltage protection Varistor Integrated into timing relay Integrated into 3RT19 16 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |