87 / 114 page ![]() Monitoring Relays 7/87 Siemens LV 1 T · 2006 3RS10, 3RS11 Temperature Monitoring Relays General data ■Overview The 3RS10 and 3RS11 temperature monitoring relays can be used for measuring temperatures in solid, liquid and gas media. The temperature is sensed by the sensor in the medium, evaluated by the device and monitored for overshoot or undershoot or for staying within an operating range (window function). The range comprises adjustable analog units with one or two threshold values, digital units to DIN 3440, which are also a good alternative to temperature controls for the low-end range, and digital units for up to 3 sensors which have been optimized for monitoring large motors. ■Design The temperature monitoring relays comply with: • IEC 60721-3-3 "Environmental conditions" • IEC 60947-5-1; VDE 0660 "Low-voltage controlgear, switchgear and systems – Electromechanical controlgear" • EN 61000-6-4 "Basic technical standard for emitted interference (Industry)" • EN 61000-6-2 "Basic technical standard for interference immunity (Industry)" • EN 50042 "Designations for terminals" •UL/CSA • DIN 3440 (3RS10 40, 3RS11 40, 3RS10 42, 3RS11 42). Connection of resistance-type thermometers 2-wire measurement When 2-wire temperature sensors are used, the resistances of the sensor and wiring are added. The resulting systematic error must be taken into account when the signal evaluator is calibrated. A jumper must be clamped between terminals T2 and T3 for this purpose. Wiring errors The errors that are generated by the wiring comprise approximately 2.5 K/ W. If the resistance of the wiring is not known and cannot be measured, the wiring errors can also be estimated using the following table. Temperature drift depending on the length and cross-section of the leads with PT100 sensors and an ambient temperature of 20 °C, in K: 3-wire measurement To minimize the effects of the line resistances, a three-wire circuit is often used. Using the additional wire, two measuring circuits can be formed of which one is used as a reference. The signal evaluator can then automatically calculate the line resistance and take it into account. Temperature setting LED "Device on voltage" LED "Relay switched" Hysteresis switch LED for display "Up and Down" keys Rotary switch for parameter selection NSB0_01421 NSB01323a PT 100 T1 T2 T3 I Cable length m Cross-section mm² 0.5 0.75 1 1.5 0 0.0 0.0 0.0 0.0 10 1.8 1.2 0.9 0.6 25 4.5 3.0 2.3 1.5 50 9.0 6.0 4.5 3.0 75 13.6 9.0 6.8 4.5 100 18.1 12.1 9.0 6.0 200 36.3 24.2 18.1 12.1 500 91.6 60.8 45.5 30.2 NSB01324a PT 100 T1 T2 T3 I I |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |