| 数据搜索系统,热门电子元器件搜索 |
|
GLS53 数据表(PDF) 43 Page - Emerson Network Power |
|
|
|||||||||||||||||||||||||||||
GLS53 数据表(HTML) 43 Page - Emerson Network Power |
|
43 / 109 page ![]() GLS253-C, GLS255-C Installation & Operating Instructions Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions P/N: A272-193 Rev 0 5/5/09 Ref: 03361002223 To comply with the published safety standards, the following must be observed when using this power supply: 1. Maximum ambient temperature for GLS255-C must not exceed 50°C. Maximum ambient temperature for GLS253-C must not exceed 50°C at 250 W, 21 A or 70°C at 125 W, 10.5 A. 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03; including the requirements for creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. 3. The power supply’s rated input voltage is automatically selected. Please refer to the specification sheet for the input voltage range. 4. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 5. This unit contains a secondary output exceeding 240 VA. When installing the unit into the end system, make sure the secondary output and the appropriate wire cannot be touched. 6. The earth ground wire must be connected only to the point marked with the earth ground symbol (on the unit). 7. The disconnection from the line must be in the end system. 8. Hazardous voltages exist in the primary circuits. Disconnect the power supply before servicing. 9. When operating with a dc input voltage range, the unit input must be protected by a dc rated fuse in the end-use installation system. 10. The internal fuse should only be replaced with a F6.3AH, 250 V ac, type 21606.3 manufactured by Littelfuse, type 50CF063H manufactured by Triad, or type S501 manufactured by Cooper. NOTE: Components, such as capacitors, may be positioned in front of the internal fuse. The unit must be protected by a fuse in the end system. 11. This equipment is considered Class I according to protection against electric shock. 12. This power supply is marked following the provisions of the Low Voltage Directive, 2006/95/EC. 13. For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for addi- tional product information and specification sheets. Mechanical Outline Output Adj. SK1 3 2 1 SK4 SK5 A B 1 8 SK3 Bus Bar SK7 Connector PIN Designation Input Connector PIN GLS253-C GLS255-C SK1 1 Neutral 2 Line 3 Earth GND Output Connector PIN GLS253-C GLS255-C Bus Bar A +6 V to +12 V +24 V to +48 V B Common SK3 1 +Sense 2 -Sense 3 Inhibit (normally open) 4 Inhibit (normally closed) 5 Common 6 C. Share 7 P OK 8 Dc OK SK4 1 Fan (+) 2 Fan (-) SK5 1 +5 V (aux) 2 Common SK7 1 Fan (+) 2 Fan (-) Output Ratings Model Output Voltage (V) 30 CFM Forced Air Cooling (unit not convection rated) Max. Output Current (A) Max. Output Power (W) GLS253-C +6 to +12 21.0 250 with cover GLS255-C +24 to +48 10.4 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |