30 / 109 page ![]() GLS120 Series Specifications Input Input range 85-264 Vac; 127-300 Vdc Frequency 47-440 Hz Inrush current 40 A max., cold start @ 25°C Efficiency 80% typical at full load EMI/RFI FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE 0878 PT3 Class B conducted Power factor 0.99 typical Safety ground leakage current <0.5 mA @ 50/60 Hz, 264 Vac input Output Maximum power 80 W for convection; 130 W with 30 CFM forced air Adjustment range ±5% min. on the main outputs Fan output 12 V @ 500 mA - 5%, +7% Standby outputs 5 V @ 500 mA ± 5% Hold-up time 20 ms @ 125 W load, 120 Vac input Overload protection Short circuit protection on all outputs Case overload protected @ 120 -135% above rating Overvoltage protection 20% to 35% above nominal output Logic Control Power failure TTL logic signal goes high 100-500 msec after main output. It goes low at least 4 msec before loss of regulation. Remote inhibit Requires a contact closure to disable the outputs, except 5 V standby. Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Operating temperature 0° to 50°C ambient. Derate each output as 2.5% per degree from 50° to 70°C. -20°C start up Storage temperature -40°C to 85°C Electromagnetic susceptibility Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity Operating; non-condensing 10% to 95% RH Vibration IEC68-2-6 to the levels of IEC721-3-2 MTBF demonstrated >550,000 hours at full load and 25°C ambient conditions Mating Connectors (SK1) AC Input Molex 09-50-8031; PINS: 08-52-0113 (SK2) DC Outputs Molex 19141-0058/0063 Spade lug (SK3)Control Signals Molex 90142-0010 (USA); PINS: 90119-2110 or Amp: 87977-3; PINS: 87309-8 Connector Kit #70-841-020, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is ±0.02” (±0.5mm). 3. Specifications are for convection rating at factory settings at 115 Vac input 25°C ,unless otherwise stated. 4. Mounting holes MH1, MH2 and MH3 should be grounded for EMI purposes. 5. Mounting MH1 is safety ground connection. 6. This power supply requires mounting on metal standoffs 0.20” (5m) in height. 7. Warranty: 2 year 8. Weight: 0.71 lb/0.32 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com Electrical Specifications Environmental Specifications |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |