| 数据搜索系统,热门电子元器件搜索 |
|
GLS53 数据表(PDF) 12 Page - Emerson Network Power |
|
|
|||||||||||||||||||||||||||||
GLS53 数据表(HTML) 12 Page - Emerson Network Power |
|
12 / 109 page ![]() GLQ150 Series Specifications Input Input range 85-132 Vac; 170-264 Vac automatically selected; 220-300 Vdc Frequency 47-63 Hz Inrush current 38 A max, cold start @ 25°C Efficiency 75% typical at full load EMI filter FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE 0878 PT3 Class B conducted Safety ground leakage current <0.5 mA @ 50/60 Hz, 264 Vac input Output Maximum power 110 W convection (75 W with cover) 150 W with 30 CFM forced air (130 W with cover) Adjustment range ±5% on main; 5-25 V on 4th output on GLQ152 & GLQ153 Cross regulation ±2% on output 1; ±3% on outputs 2, 3 & 4 Hold-up time 20 ms @ 110 W load at nominal line Overload protection Short circuit protection on all outputs Case overload protected @ 110 -145% above peak rating Overvoltage protection 5.7 to 6.7 Vdc on main output Minimum Load 2 A for the first output, 0.1 A for second and third outputs, 0.5 A for the 4th output of GLQ154 Logic Control Power failure TTL logic signal goes high 50-150 msec after 5 V output. It goes low at least 3 msec before loss of regulation. Remote inhibit Requires an external TTL high signal to inhibit outputs Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Operating temperature 0° to 50°C ambient. Derate each output 2.5% per degree from 50° to 70°C Storage temperature -40°C to 85°C Temperature coefficient ±0.04% per °C Electromagnetic susceptibility Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Humidity Operating; non-condensing 5% to 95% Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75 G peak 5 Hz to 500 Hz, operational MTBF demonstrated >550,000 hours at full load and 25°C ambient conditions Mating Connectors AC Input (SK4) Molex 09-50-8051 (USA) Molex 09-91-0500 (UK); PINS: 08-58-0111 Aux DC Output Power Fail (SK2) Molex 09-50-8091 (USA) Molex 09-91-0900 (UK); PINS: 08-58-0111 Remote Sense/ Remote Inhibit (SK1) Molex 51110-0851 (USA) PINS: 503-94-8100 Connector Kit #70-841-010, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is ±0.02” (±0.5mm). 3. Specifications are for convection rating at factory settings unless otherwise stated. 4. Remote inhibit requires an external 5 V @ 10 mA to activate. 5. Mounting (6-32) maximum insertion depth is .12”. 6. Warranty: 2 years 7. Weight: 1.75 lbs/0.80 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com Electrical Specifications Environmental Specifications |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |