31 / 109 page ![]() GLS150 Series Installation & Operating Instructions P/N: A272-169 Rev 2 12/29/09 Ref: 03361001994 Installation & Safety To comply with the published safety standards, the following must be observed when using this power supply: 1. Maximum ambient temperature for the power supply must not exceed 50°C. 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03; including the requirements for creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. 3. The power supply’s rated input voltage is automatically selected. Please refer to the specification sheet for the input voltage range. 4. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 5. The earth ground wire must be connected only to the point marked with the earth ground symbol (on the unit). 6. Hazardous voltages exist in the primary circuits. Disconnect the power supply before servicing. 7. When operating with a dc input voltage range, the unit input must be protected by a dc rated fuse in the end-use installation system. 8. The internal fuse should only be replaced with a 5 A, 250 V ac, type SP0001.1011 manufactured by Schurter AG, type 216005 manufactured by Littelfuse or type S501 manufactured by Cooper. 9. This power supply is marked following the provisions of the Low Voltage Direc- tive, 2006/95/EC. For technical assistance, contact SolaHD Technical Support at (800) 377-4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. Output Ratings Model Output Voltage(V) ConvectionCooling 30CFMForcedAirCooling Max.Output Current(A) Max.Output Power(W) Max.Output Current(A) Max.Output Power(W) GLS152 +5 22.0 75 with cover 110 without cover 30.0 130 with cover 150 without cover GLS153 +12 to +15 9.1 12.5 GLS155 +24 to +28 4.5 6.2 Mechanical Outline 5 SK1 1 F5AH 1 2 250V 1 2 3 4 5 6 7 9 8 SK2 SK3 SK4 3 1 8 Output Adjust Connector PIN Designation OutputConnector PIN GLS152 GLS153 GLS155 SK1 1 Inhibit -ve 2 Inhibit +ve 3 Secondary Vcc 4 No connection 5 Common 6 -Sense 7 +Sense 8 C-Share SK2 1, 2, 3, 4, 8, 9 Not used 5 Common 6 No connection 7 P OK SK3 T.B. 2 +5 V +12 V to +15 V +24 V to +28 V T.B. 1 Common InputConnector PIN GLS152 GLS153 GLS155 SK4 1 Earth GND 2 PIN removed 3 Line 4 PIN removed 5 Neutral |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |