| 数据搜索系统,热门电子元器件搜索 |
|
GLS53 数据表(PDF) 19 Page - Emerson Network Power |
|
|
|||||||||||||||||||||||||||||
GLS53 数据表(HTML) 19 Page - Emerson Network Power |
|
19 / 109 page ![]() GLQ352-C, GLQ352-CEF Installation & Operating Instructions Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions P/N: A272-195 Rev 0 5/6/09 Ref: 03366200121 To comply with the published safety standards, the following must be observed when using this power supply: 1. Maximum ambient temperature for the power supply must not exceed 50°C. 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03; including the requirements for creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. 3. The power supply’s rated input voltage is automatically selected. Please refer to the specification sheet for the input voltage range. 4. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 5. This unit contains a secondary output exceeding 240 VA. When installing the unit into the end system, make sure the secondary output and the appropriate wire cannot be touched. 6. The earth ground wire must be connected only to the point marked with the earth ground symbol (on the unit). 7. The disconnection from the line must be in the end system. 8. Hazardous voltages exist in the primary circuits. Disconnect the power supply before servicing. 9. When operating with a dc input voltage range, the unit input must be protected by a dc rated fuse in the end-use installation system. 10. The internal fuse should only be replaced with a F10AH, 250 V ac, type 216010 manufactured by Littelfuse or type SP001.1014 manufactured by Schurter AG. 11. This equipment is considered Class I according to protection against electric shock. 12. This power supply is marked following the provisions of the Low Voltage Directive, 2006/95/EC. 13. For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for addi- tional product information and specification sheets. Output Ratings Model Output Voltage (V) 30 CFM Forced Air Cooling (unit not convection rated) Max. Output Current (A) Max. Output Power (W) GLQ352-C (-CEF) +5 50.0 350 with cover +12 12.0 -12 6.0 +3.3 to +24 6.0 Mechanical Outline Top Pot = V4 adj. Bottom Pot = Main adj. SK1 3 2 1 SK6 SK4 SK5 A B 6 5 4 3 2 1 1 10 SK2 SK3 Bus Bar Connector PIN Designation Input Connector PIN Designation SK1 1 Neutral 2 Line 3 Earth GND Output Connector PIN Designation Bus Bar A +5 V B Common SK2 1 +12 V 2 Common 3 Common 4 -12 V 5 Return (float) 6 +3.3 V to +24 V adj. SK3 1 +Sense V4 2 -Sense V4 3 +Sense V1 4 -Sense V1 5 P OK 6 C. Share 7 Dc OK 8 Inhibit 9 Inhibit 10 Common SK4 1 +12 V (aux) 2 Common SK5 1 +5 V (aux) 2 Common SK6 1 12 V fan (+) 2 Fan (-) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |