| 数据搜索系统,热门电子元器件搜索 |
|
GLS53 数据表(PDF) 13 Page - Emerson Network Power |
|
|
|||||||||||||||||||||||||||||
GLS53 数据表(HTML) 13 Page - Emerson Network Power |
|
13 / 109 page ![]() GLQ172 Installation & Operating Instructions Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions P/N: A272-192 Rev 0 6/1/09 Ref: 03366202130 To comply with the published safety standards, the following must be observed when using this power supply: 1. Maximum ambient temperature for the power supply must not exceed 50°C. 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03; including the requirements for creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. 3. The ac-dc input connector is approved as a component of the power supply, however, it was not specifically evaluated to IEC60320. 4. This power supply is approved and certified for the rated voltage range of 100 V ac to 250 V ac and/or 120 V dc (minimum) to 300 V dc (maximum). 5. The earth ground wire must be connected only to the point marked with the earth ground symbol (on the unit). 6. The disconnection from the line must be in the end system. 7. When operating with a dc input voltage range, the dc source must be rectified from a mains supply not exceeding 250 V ac. The unit input must also be protected by a dc rated fuse in the end-use installation system. 8. The internal fuse (F1) should only be replaced by a 4 A, 250 V ac, type GDA-V/S501 manufactured by Bussman, type 19194 manufactured by Wickmann, or type 226004 manufactured by Littelfuse. 9. This equipment is considered Class I according to protection against electric shock. 10. This power supply is marked following the provisions of the Low Voltage Directive, 2006/95/EC. 11. For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for addi- tional product information and specification sheets. Output Ratings Output Voltage (V) Convection Cooling 30 CFM Forced Air Cooling Max. Output Current (A) Max. Output Power (W) Max. Output Current (A) Max. Output Power (W) V1: +3.3 to +5.7 15.0 110 without cover 30.0 175 with or without cover V2: +12.0 6.0 8.0 V3: -12.0 to -15.0 1.5 3.0 V4: +3.3 to +25.0 2.0 5.0 +5 VSB 0.2 0.2 Mechanical Outline 5 3 1 SK4 V3 V4 V1 P252 P251 SK1 SK2 SK3 10 6 5 1 9 1 Connector PIN Designation Output Connector PIN Designation SK1 1 V2 SWP (Single Wire Parallel) (No connection - optional) 2 +5 VSB 3 +V2 sense (No connection - optional) 4 V1 SWP (Single Wire Parallel) 5 Common 6 +V1 sense 7 Sense common 8 Remote inhibit 9 Dc power good 10 Power fail SK2 1,2 V2 3, 4, 5 Common 6 V3 7 P OK 8 V4 9 V4 (Return) SK3 P251 V1 P252 V1 Input Connector PIN Designation SK4 1 Earth GND 3 Line 5 Neutral |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |