70 / 109 page ![]() GLS53-I Installation & Operating Instructions P/N: A272-207 Rev 0 6/29/09 Ref: 03370201560 ©2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions GLS53-I is a commercial designation of model number LPS53(-I). To comply with the published safety standards, the following must be observed when using this power supply: 1. Maximum ambient temperature for the power supply must not exceed 50°C. The power supply has been evaluated for use in 70°C at half load and 80°C at quarter load. 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03. The safety requirements include creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. 3. This power supply is approved and certified for the rated voltage range of 100 V ac to 240 V ac. 4. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 5. The disconnection from the line must be in the end system. 6. The unit must be protected with dc rated fuse when operating in a dc input voltage. 7. The internal fuse should only be replaced with a 3.15A, 250 V ac, type TE5/392 manufac- tured by Wickmann. 8. This equipment is considered Class I according to protection against electric shock. 9. This power supply is marked following the provisions of the Low Voltage Directive, 2006/95/EC. 10. For technical assistance, contact SolaHD Technical Support at (800) 377-4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for addi- tional product information and specification sheets. Output Ratings Output Voltage (V) Convection Cooling Max. Output Current (A) Max. Output Power (W) +12 5.0 60 Connector PIN Designation Input Connector PIN Designation SK1 1 Line 3 Neutral Output Connector PIN Designation SK2 1 +12 V 2 +12 V 3 Common 4 Common 5 -Sense 6 +Sense Mechanical Outline & Dimensions Mounting Hole .16 [4.0] 4 X 3.73 [94.7] 4.00 [101.6] .16 [4.0] Earth GND 3 F1 1 M1 ~ ~ T2 6 1 Output Voltage Adjust Pot M2 SK1 SK2 Top View Side View All dimensions are in inches [mm]. Maximum screw head diameter is .22″ [5.6 mm]. Mounting holes M1 and M2 should be grounded for EMI purposes. Mounting hole M1 is an earth ground connection. CAUTION! Do not accidentally connect the ac connector to the dc output. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |