| 数据搜索系统,热门电子元器件搜索 |
|
GLS53 数据表(PDF) 22 Page - Emerson Network Power |
|
|
|||||||||||||||||||||||||||||
GLS53 数据表(HTML) 22 Page - Emerson Network Power |
|
22 / 109 page ![]() GLS100-M Series Installation & Operating Instructions Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions P/N: A272-196 Rev 0 5/7/09 Ref: 03366206070 To comply with the published safety standards, the following must be observed when using this power supply: 1. Maximum ambient temperature for the power supply must not exceed 50°C. Derate each output 2.5% per degree from 50°C to 70°C ambient temperature. 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, CSA22.2 No. 60950-1-03, UL60601-1, EN60601-1, IEC60601-1, and CSA22.2 No. 601.1. The safety requirements include creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. 3. The ac-dc input connector is approved as a component of the power supply, however, it was not specifically evaluated to IEC60320. 4. This power supply is approved and certified for the rated voltage range of 100 V ac to 250 V ac and/or 120 V dc minimum to 300 V dc maximum. 5. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 6. The earth ground wire must be connected only to the point marked with the earth ground symbol (on the unit). 7. The disconnection from the line must be in the end system. 8. Hazardous voltages exist in the primary circuits. Disconnect power supply before servicing. 9. When operating with a dc input voltage range, the unit input must be protected by a dc rated fuse in the end-use installation system. 10. The internal fuses (F1 & F2) should only be replaced with a F2A5, 250 V ac, type 392 manufactured by Wickmann or type RST manufactured by Belfuse. NOTE: The power supply has a fuse on the neutral line. 11. The power supply has no patient applied part. 12. This equipment is considered Class I according to protection against electric shock. 13. This power supply is marked following the provisions of the Low Voltage Directive, 2006/95/EC. 14. For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for addi- tional product information and specification sheets. Output Ratings Model Output Voltage (V) Convection Cooling 30 CFM Forced Air Cooling Max. Output Current (A) Max. Output Power (W) Max. Output Current (A) Max. Output Power (W) GLS102-M +5 16.0 80 24.0 120 +12_FAN 0.5 1.0 GLS103-M +12 8.3 100 12.5 150 +12_FAN 0.5 1.0 GLS104-M +15 6.7 10.0 +12_FAN 0.5 1.0 GLS105-M +24 4.2 6.25 +12_FAN 0.5 1.0 GLS108-M +48 2.09 3.1 +12_FAN 0.5 1.0 Connector PIN Designation Input Connector PIN Designation SK1 1 Neutral 3 Line CN1 GND Output Connector PIN Designation SK2 1 Common 2 3 4 5 +Vout 6 7 8 SK203 1 GND 2 Power fail 3 -Remote sense 4 +Remote sense SK5 1 +12 V_FAN 2 +12 V_FAN 3 Common fan 4 Common fan |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |