| 数据搜索系统,热门电子元器件搜索 |
|
GLS53 数据表(PDF) 78 Page - Emerson Network Power |
|
|
|||||||||||||||||||||||||||||
GLS53 数据表(HTML) 78 Page - Emerson Network Power |
|
78 / 109 page ![]() GLS60 Series, GLS60-M Series Installation & Operating Instructions Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions P/N: A272-198 Rev 0 5/12/09 Ref: 03361001333/03366200541 To comply with the published safety standards, the following must be observed when using this power supply: 1. Maximum ambient temperature for the power supply must not exceed 50°C. 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03 for GLS62, GLS63, GLS64, and GLS65; UL60601-1, EN60601-1, IEC60601-1, and CSA22.2 No. 60601-1-M90 for GLS63-M, GLS64-M, and GLS65-M. The safety requirements include creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. 3. The power supply’s rated input voltage is automatically selected for GLS62, GLS63, GLS64, and GLS65. Please refer to the specification sheet for the input voltage range. GLS63-M, GLS64-M, and GLS65-M are approved and certified for the rated voltage range of 100 V ac to 250 V ac and/or 140 V dc to 300 V dc. 4. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 5. The earth ground wire must be connected only to the point marked with the earth ground symbol (on the unit). 6. The disconnection from the line must be in the end system. 7. Hazardous voltages exist in the primary circuits. Disconnect the power supply before servicing. 8. When operating with a dc input voltage range, the unit input must be protected by a dc rated fuse in the end-use installation system. 9. The internal fuse should only be replaced with a 3.15 A, 250 V ac, type SP0001.1009 manufactured by Schurter AG, type 2163.15 manufactured by Littelfuse, or type S501 manufactured by Cooper. 10. This power supply is not suitable for direct contact to the patient. 11. This equipment is considered Class I according to protection against electrick shock. 12. This power supply is marked following the provisions of the Low Voltage Directive, 2006/95/EC. 13. For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. Mechanical Outline R16 D16A 1 6 SK201 V Adj. Pot SK2 GND M1 M2 1 3 SK1 T1 Connector PIN Designation Input Connector PIN GLS62 GLS63 (-M) GLS64 (-M) GLS65 (-M) SK1 1 Neutral 3 Line Output Connector PIN GLS62 GLS63 (-M) GLS64 (-M) GLS65 (-M) SK2 1 +5 V +12 V +15 V +24 V 2 3 4 Common 5 6 SK201 1 +Sense 2 -Sense NOte: Mounting holes M1 and M2 should be grounded for EMI purposes. Mounting hole M1 is a safety ground connection. Output Ratings Model Output Voltage (V) Convection Cooling 30 CFM Forced Air Cooling Max. Output Current (A) Max. Output Power (W) Max. Output Current (A) Max. Output Power (W) GLS62 +5 12.0 60 16.0 80 GLS63 (-M) +12 5.0 6.7 GLS64 (-M) +15 4.0 5.3 GLS65 (-M) +24 2.5 3.3 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |