52 / 109 page ![]() GLS40 Series, GLS40-M Series Installation & Operating Instructions P/N: A272-180 Rev 1 01/06/10 Ref: 03361001145 Installation & Safety To comply with the published safety standards, the following must be observed when using this power supply: 1. Maximum ambient temperature for the power supply must not exceed 50°C. The power supply has been evaluated for use in 70°C at half load. 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03 for GLS42, GLS43, GLS44, and GLS45; UL60601-1, EN60601-1, IEC60601-1, and CSA22.2 No. 60601-1-M90 for GLS42-M, GLS43-M, GLS44-M, and GLS45-M. The safety requirements include creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. 3. The power supply’s rated input voltage is automatically selected. Please refer to the specification sheet for the input voltage range. 4. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 5. The earth ground wire must be connected only to the point marked with the earth ground symbol (on the unit). 6. Hazardous voltages exist in the primary circuits. Disconnect the power supply before servicing. 7. When operating with a dc input voltage range, the unit input must be protected by a dc rated fuse in the end-use installation system. 8. The internal fuse should only be replaced with a 2.5 A, 250 V ac, type SP0001.1008 manufactured by Schurter AG or type 21602.5 manufactured by Littelfuse. 9. GLS42-M, GLS43-M, GLS44-M, and GLS45-M have no patient applied part. 10. This equipment is considered Class I according to protection against electric shock. 11. This power supply is marked following the provisions of the Low Voltage Directive, 2006/95/EC. For technical assistance, contact SolaHD Technical Support at (800) 377-4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. Mechanical Outline SK2 3 1 SK1 M2 M1 1 2 3 4 5 6 Voltage Adj. Pot Connector PIN Designation InputConnector PIN GLS42(-M) GLS43(-M) GLS44(-M) GLS45(-M) SK1 1 Line 3 Neutral OutputConnector PIN GLS42(-M) GLS43(-M) GLS44(-M) GLS45(-M) SK2 1 +5 V +12 V +15 V +24 V 2 3 4 Common 5 6 SK201 1 +Sense 2 -Sense NOte:Mounting holes M1 and M2 should be grounded for EMI purposes. Mounting hole M1 is an earth ground connection. Output Ratings Model Output Voltage(V) ConvectionCooling 30CFMForcedAirCooling Max.Output Current(A) Max.Output Power(W) Max.Output Current(A) Max.Output Power(W) GLS42(-M) +5 8.0 40 11.0 55 GLS43(-M) +12 3.3 4.5 GLS44(-M) +15 2.6 3.6 GLS45(-M) +24 1.7 2.3 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |