55 / 109 page ![]() GLS503-CF, GLS503-M-CF Installation & Operating Instructions P/N: A272-173 Rev 2 01/06/10 Ref: 03366205360 Installation & Safety To comply with the published safety standards, the following must be observed when using this power supply: 1. Maximum ambient temperature for the power supply must not exceed 50°C. Derate each output 2.5% per degree from 50°C to 70°C ambient temperature. 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03 for the GLS503-CF; UL60601-1, EN60601-1, IEC60601-1, and CSA22.2 No. 60601-1 for the GLS503-M-CF. The safety requirements include creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. 3. The ac-dc input connector is approved as a component of the power supply, however, it was not specifically evaluated to IEC60320. 4. This power supply is approved and certified for the rated voltage range of 100 V ac to 250 V ac and/or 120 V dc (minimum) to 300 V dc (maximum). 5. The maximum output power of the supply must not exceed the rating indicated in the speci- fication sheet. 6. This power supply contains a +12 V output exceeding 240 VA. When installing the unit into the end system, make sure the outputs and the appropriate wire cannot not be touched. 7. The disconnection from the line must be in the end system. 8. Hazardous voltages exist in the primary circuits. Disconnect power supply before servicing. 9. The internal fuses (F1, F2) should only be replaced by a F10AH A, 250 V ac, type 216010 MXEP manufactured by Littelfuse or type 5HFP manufactured by Belfuse. NOTE: The power supply has a fuse on the on the neutral line. 10. The earthing conductor in the end system should not be less than 8 awg (10 mm2) in a cross-sectional area. 11. GLS503-M-CF has no patient applied part. 12. The equipment is considered Class I according to protection against electric shock. 13. This power supply is marked following the provisions of the Low Voltage Directive, 2006/95/EC. For technical assistance, contact SolaHD Technical Support at (800) 377-4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. Mechanical Outline CN1 SK7 SK4 SK5 SK6 1 2 3 5 1 10 6 Connector PIN Designation InputTerminal PIN Designation CN1 1 Line 2 Neutral 3 Earth GND OutputConnector PIN Designation SK4 OR-ing terminal SK5 +12 V main SK6 Common/Return SK7(SignalOutput) 1 V1 SWP (Single Wire Parallel) 2 -Remote sense 3 +Remote sense 4 +5 V standby 5 Standby return 6 +12 V (fan out) 7 Common 8 Remote inhibit 9 Dc power good 10 Power fail Note: For information on the I2C Header (CN403) and Fan Header (SK8), please contact Technical Support. Output Ratings OutputVoltage(V) ConvectionCooling 30CFMForcedAirCooling Max.Output Current(A) Max.Output Power(W) Max.Output Current(A) Max.Output Power(W) +12 16.67 200 41.67 500 with cover fan +5 standby 1.00 2.00 +12 (fan out) 0.50 0.50 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |