| 数据搜索系统,热门电子元器件搜索 |
|
ST25R3916 数据表(PDF) 64 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ST25R3916 数据表(HTML) 64 Page - STMicroelectronics |
|
64 / 157 page ![]() Application information ST25R3916/7 64/157 DS12484 Rev 4 4.4.8 Measure amplitude This command measures the amplitude of the RF signal on the RFI inputs and stores the result in the A/D converter output register. This command enables the transmitter and amplitude detector. The transmitter drives the antenna, and the amplitude detector converts the differential RF signal received back between RFI1 and RFI2 into a proportional DC voltage. This DC voltage is converted with the A/D converter in absolute conversion mode into an 8-bit value and stored in the A/D converter output register. The amplitude detector conversion gain is 0.6 VinPP / Vout referenced to the RF signal on a single RFI pin. Thus, one LSB of the A/D converter output represents 13.02 mVPP on either of the RFI inputs. Note: The maximum allowed voltage level on an RFI pin is 3 VPP. This results in 1.8 V output DC voltage of the amplitude detector and produces a value of E6h after A/D conversion. Duration time: 25 μs max. 4.4.9 Reset RX gain This command initializes the AGC, Squelch and RSSI block and resets the gain reduction to the value set in Receiver configuration register 4. Sending this command also stops any ongoing squelch process. 4.4.10 Adjust regulators When this command is sent, then the transmitter and receiver are enabled to ensure a high current draw and the regulated voltage VDD_RF is set 250 mV below the power supply level of VDD_TX. Before sending the adjust regulator command it is required to toggle the bit reg_s by setting it first to 1 and then reset it to 0. After the adjustment is completed the state of the transmitter and receiver prior to the command execution is restored (either enabled or disabled). Duration time: 5 ms max. This command is not accepted if external definition of the regulated voltage is selected in the Regulator voltage control register (bit reg_s is set to 1). 4.4.11 Measure phase This command measures the phase difference between the signals on the RFO outputs and the signals on the RFI inputs and stores the result in the A/D converter output register. This command enables the transmitter and phase detector, and performs an A/D conversion of the output of the phase detector with the A/D converter in relative mode. The phase measurement results can be calculated using the following formulas: 0 ≤ Φ ≤ 17º: result = 255 17 < Φ < 163º: angle [º] = 17 + (1 -result / 255) * 146 163 ≥ Φ ≥ 180º: result = 0 Duration time: 25 μs max. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |