| 数据搜索系统,热门电子元器件搜索 |
|
M58LR128HT 数据表(PDF) 35 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M58LR128HT 数据表(HTML) 35 Page - STMicroelectronics |
|
35 / 112 page ![]() M58LR128HT, M58LR128HB Status Register 35/112 5.3 Erase/Blank Check Status bit (SR5) The Erase/Blank Check Status bit is used to identify if there was an error during a Block Erase operation. When the Erase/Blank Check Status bit is High (set to ‘1’), the Program/Erase Controller has applied the maximum number of pulses to the block and still failed to verify that it has erased correctly. The Erase/Blank Check Status bit should be read once the Program/Erase Controller Status bit is High (Program/Erase Controller inactive). The Erase/Blank Check Status bit is also used to indicate whether an error occurred during the Blank Check operation: if the data at one or more locations in the block where the Blank Check command has been issued is different from FFFFh, SR5 is set to '1'. Once set High, the Erase/Blank Check Status bit must be set Low by a Clear Status Register command or a hardware reset before a new erase command is issued, otherwise the new command will appear to fail. 5.4 Program Status bit (SR4) The Program Status bit is used to identify if there was an error during a program operation. The Program Status bit should be read once the Program/Erase Controller Status bit is High (Program/Erase Controller inactive). When the Program Status bit is High (set to ‘1’), the Program/Erase Controller has applied the maximum number of pulses to the Word and still failed to verify that it has programmed correctly. Attempting to program a '1' to an already programmed bit while VPP = VPPH will also set the Program Status bit High. If VPP is different from VPPH, SR4 remains Low (set to '0') and the attempt is not shown. Once set High, the Program Status bit must be set Low by a Clear Status Register command or a hardware reset before a new program command is issued, otherwise the new command will appear to fail. 5.5 VPP Status bit (SR3) The VPP Status bit is used to identify an invalid voltage on the VPP pin during program and erase operations. The VPP pin is only sampled at the beginning of a program or erase operation. Program and erase operations are not guaranteed if VPP becomes invalid during an operation When the VPP Status bit is Low (set to ‘0’), the voltage on the VPP pin was sampled at a valid voltage. When the VPP Status bit is High (set to ‘1’), the VPP pin has a voltage that is below the VPP Lockout Voltage, VPPLK, the memory is protected and program and erase operations cannot be performed. Once set High, the VPP Status bit must be set Low by a Clear Status Register command or a hardware reset before a new program or erase command is issued, otherwise the new command will appear to fail. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |