| 数据搜索系统,热门电子元器件搜索 |
|
L9908 数据表(PDF) 94 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9908 数据表(HTML) 94 Page - STMicroelectronics |
|
94 / 152 page ![]() Note: The application software must configure T_ofd_blank to ensure that the motor is not running and the phases are not energized. For some applications the maximum available T_ofd_blank configuration could be too short, the application software then shall enable the OFD circuit with an additional delay after disabling the bridge drivers. Table 87. OFD electrical characteristics Symbol Parameter Test condition Min Typ Max Unit Notes OFD_rvef OFD phase reference voltage in with no fault OFDn_EN = 01 OFDi,j_EN = 10 2 2.7 3.1 V - OFD_vpd_ol OFD open load voltage in pd mode OFDn_EN = 10 SHS_n = No load - - 0.9 V - OFD_ipu OFD pull up current capability OFDn_EN = 01 2.25 - 3.3 mA - OFD_ipd OFD pull down current capability OFDn_EN = 10 0.6 0.75 0.9 mA It includes an ILEAK contribution OFD_scb_th OFD_SCB detection threshold - - SLS_n+1.7 - V Not subject to production test OFD_scg_th OFD_SCG detection threshold - - VDH-0.7 - V Not subject to production test T_ofd_flt OFD fault detection filter time - 85 100 115 μs Digital filter T_ofd_blank_acc OFD Blanking Time accuracy CLK_SSM_EN = 0 -15 - 15 % - Note: All parameters are guaranteed, and tested, in the voltage ranges reported above in Table 5 unless otherwise specified. Where not specified the parametrical operating range equals the functional operating range. 5.15 On State Diagnosis (OND) L9908 implements a monitoring unit to detect failure condition affecting the load during the half bridges ON state by monitoring the voltage drain-source drop across the Ext. FET. The ON state diagnosis unit is composed by a dedicated VDS comparator for each HS and LS Ext. FET that constantly monitors the voltage drop during FET`s ON state. ON State Load Failure Mode Detection: • Short-circuit to ground at one SHS_n terminals → HSn_STG flag is set to 1 • Short-circuit to battery at one SHS_n terminals → LSn_STB flag is set to 1 The ON state diagnosis can be disabled by a dedicated SPI bit as follows: Table 88. OND enable bits ONDn_DIS Description 0 ON State diagnosis enabled on n-th HS and LS (Default) 1 ON State diagnosis disabled on n-th HS and LS When the OND monitoring is disabled while having the fault flag set, the flag will not be cleared until SPI read. If VDH-SHS_n ≥ V_ond_hs_th occurs for an interval longer than T_ond_flt filter time, the HSn_STG flag is set. The error flag remains set until the failure condition is removed and the flag is cleared by the SPI command. If SHS_n-SLSn ≥ V_ond_ls_th occurs for an interval longer than T_ond_flt filter time, the LSn_STB flag is set. The error flag remains set until the failure condition is removed and the flag is cleared by the SPI command. L9908 Functional description DS13546 - Rev 5 page 94/152 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |