27 / 152 page ![]() 2. NVM READ MODE Internal supply and reference voltage/currents are available possibly exceeding spec parametrical ranges. The main logic is out of reset (INT_RST = ’1’, internal signal). Main functions are disabled: – Gate driver supply stage disabled – Half Bridge gate drivers stages are in HIZ mode while LS half Bridge gate drivers stages are shutdown (SAFE-HIZ) – Current monitors chains and monitoring units are disabled – SPI Read is available while SPI write is disabled In this mode a CRC check on NVM data is first performed: – If no CRC error is detected the NVM content is deployed into main logic register – If a CRC error is detected the related main logic registers are reset to default values (all ‘0’) and NVM_CRC_FAIL flag is set to ‘1’ Note: All parameters are guaranteed and tested in the voltage ranges reported in Table 5 unless otherwise specified. Where not specified the parametrical operating range equals the functional operating range. Table 15. Power up/down timings Symbol Parameter Min Typ Max Unit Notes T_nvm NVM data deploy & CRC duration - - 2 ms Not subject to production test 3. NORMAL MODE Internal supply and reference voltage/currents are available and within spec ranges. The main logic is out of reset (INT_RST = ’1’, internal signal). Main functions: – Half Bridge gate drivers status depends on disable logic assessment (Functional or SAFE_DIS) – Gate driver supply stage status depends on configuration – Current monitors chains and monitoring units status depend on configuration – SPI Read/Write operations are available 4. SAFE OFF MODE Internal supply and reference voltage/currents are available and within spec ranges. The main logic is out of reset (INT_RST = ’1’, internal signal). Main functions: – Gate driver supply stage is disabled – HS and LS states are in SAFE_OFF or SAFE_HIZ depending on fault reaction as described in Table 17 – Current monitors chains and monitoring units status depend on configuration – SPI Read/Write operations are available 5. SELF TEST MODE Internal supply and reference voltage/currents are available and within spec ranges. The main logic is out of reset (INT_RST = ’1’, internal signal). Main functions: – Gate driver supply stage depends on disable logic assessment – Half Bridge gate drivers are disabled (SAFE-DIS) – Current monitors chains and monitoring units status depend on configuration – SPI Read is available while SPI write is disabled 6. CONFIG MODE Internal supply and reference voltage/currents are available and within spec ranges. The main logic is out of reset (INT_RST = ’1’, internal signal). Main functions: – Half Bridge gate drivers status depends on disable logic assessment (Functional or SAFE_DIS) – Gate driver supply stage status depends on configuration – Current monitors chains and monitoring units status depend on configuration – SPI Read/Write operations are available Three SPI readable flags are present to read-back the operational state machine status according to the following table: L9908 Functional description DS13546 - Rev 5 page 27/152 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |