34 / 152 page ![]() 3. Fault danger for the application is considered low, the fault can be ignored with no corrective action applied nor internal or external. The following table details the fault reaction configurations available for the different fault events. Table 26. Internal managed faults reaction details Fault flag Device fault Half Bridge fault FRC available STD_VGS_n=1 - X (1)(2)(3) HSn_STG = 1 - X (1)(2)(3) LSn_STG=1 - X (1)(2)(3) VDH_UV=1 X - (1)(3) VDH_OV=1 X - (1)(3) VBP_UV=1 X - (1)(3) VBP_OV=1 X - (1)(3) 1. Fault danger for the application is considered high, the corrective action shall be taken as soon as it is detected by the device itself by disabling all half bridges and charge pumps. 2. Fault danger for the application is considered high, the corrective action shall be taken as soon as it is detected by the device itself by disabling only the half bridge on which the fault is present still allowing a reduced performance operation. 3. Fault danger for the application is considered low, the fault can be ignored with no corrective action applied nor internal or external. Note: • While other configurations are available for all FHC faults the configuration 01 is available only on a limited subset. In faults that do not support such an FRC the configuration 01 is reserved. • For VDH_UV, VDH_OV, VBP_UV, VBP_OV and CFG_CRC_FAIL the configuration 01 has the same effect as configuration 10 and 11. 5.6.1.2 Fault Output Redirection (FOR) L9908 implements a double source of fault signaling by pin FS_FLAG and by a dedicated SPI field present in every frame. FS_FLAG output can be configured in push-pull mode or in open-drain mode by means of the following SPI bit: Table 27. Fault output redirection configuration bit FS_FLAG_CFG Description 0 Push-pull (Default) 1 Open-drain The pin FS_FLAG is asserted LOW and the IC ERR flag is set to ‘1’ if a STD fault is detected which has been configured to be redirected externally via <FLT_REF>_REDIRECT_CFG. The pin FS_FLAG is asserted HIGH and IC ERR flag is set to ‘10’ when the STD failure condition disappears. Table 28. IC ERR status bits IC ERR1 IC ERR0 Description 0 0 NO STD Fault (Default) 0 1 NO STD Fault 1 0 NO STD Fault 1 1 STD Fault L9908 Functional description DS13546 - Rev 5 page 34/152 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |