| 数据搜索系统,热门电子元器件搜索 |
|
L9908 数据表(PDF) 32 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9908 数据表(HTML) 32 Page - STMicroelectronics |
|
32 / 152 page ![]() Symbol Parameter Min Typ Max Unit Notes T_selftest_time_out SELF TEST Mode Time-out 0.77 0.88 0.99 ms Not subject to production test 5.6 Fault Handling Management (FHM) The fault set is divided into two main categories based on the required corrective actions: • STD (Shutdown Faults): this set includes faults which are highly dangerous for the IC or the application and that needs a quick corrective action to avoid harming; • WRN (Warnings): this set includes all those faults against which the application and the device are tolerant and the corrective action can be waived or delayed. L9908 allows a certain degree of fault management customization a subset of available enabled faults can be configured by setting the proper FHC registers. Table 24. Fault summary Fault Flag Source Diagnosis Self-Check Failure Reaction Fault Description INT_RST=1 Internal Supply Monitor Yes RESET Under-voltage on V3V3_ANA INT_RST=1 Internal Supply Monitor Yes RESET Under-voltage on V3V3_DIG INT_RST=1 Internal Supply Monitor Yes RESET Over-voltage on V3V3_ANA INT_RST=1 Internal Supply Monitor Yes RESET Over-voltage on V3V3_DIG INT_RST=1 VDD Monitor Yes RESET Under-voltage on VDD VDD_OV=1 VDD Monitor Yes SAFE-OFF Over-voltage on VDD INT_RST=1 ICM Yes RESET & SAFE_OFF Main clock stuck violation CLK1_ERR=1 CLK2_ERR=1 CLK2_TIME_OUT=1 ICM No Flag only (NORMAL) Oscillators mismatch or auxiliary clock stuck violation PGND_LOSS=1 AGND_LOSS=1 DGND_LOSS=1 GLM Yes Flag only (NORMAL) Loss of power or signal grounds OTM_SD=1 OTM No SAFE-OFF Thermal shutdown OTM_WR=1 OTM No Flag only (NORMAL) Thermal warning STDn_PWM =1 [n=1,2,3] STD on PWM No Ignore overlapping PWM command Shoot through on half bridge n (PWM input) STDn_VGS =1 [n=1,2,3] STD on VGS No Configurable Shoot through on half bridge n (Ext. FET Vgs) HSn_STG = 1 [n=1,2,3] OND Yes Configurable Short to ground on SHS_n LSn_STB=1 [n=1,2,3] OND Yes Configurable Short to battery on SHS_n HS2_OFD=1 LSn_OFD=0 [n=1,2,3] OFD Yes Flag only (NORMAL) Short to ground on one or multiple motor phase HS2_OFD=0 LSn_OFD=1 OFD Yes Flag only (NORMAL) Short to battery on one or multiple motor phase L9908 Functional description DS13546 - Rev 5 page 32/152 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |