107 / 188 page ![]() Pre-Production WM8904 w PP, Rev 3.3, September 2012 107 A list of possible TOCLK rates is provided in Table 66. TOCLK_RATE TOCLK_RATE_X4 TOCLK_RATE_DIV16 TOCLK FREQ (Hz) PERIOD (ms) 1 1 0 1000 1 0 1 0 500 2 1 0 0 250 4 0 0 0 125 8 1 1 1 62.5 16 0 1 1 31.25 32 1 0 1 15.625 64 0 0 1 7.8125 128 Table 66 TOCLK Rates ADC / DAC OPERATION AT 88.2K / 96K The WM8904 supports ADC or DAC operation at 88.2kHz and 96kHz sample rates. This section details specific conditions applicable to these operating modes. Note that simultaneous ADC and DAC operation at 88.2kHz or 96kHz is not possible. For DAC operation at 88.2kHz or 96kHz sample rates, the available clocking configurations are detailed in Table 67. DAC operation at these sample rates is achieved by setting the SAMPLE_RATE field to half the required sample rate (eg. select 48kHz for 96kHz mode). For DAC operation at 88.2kHz or 96kHz sample rates, the ADCs must both be disabled (ADCL_ENA = 0 and ADCR_ENA = 0). Also, the DAC_OSR128 register must be set to 0. ReTune TM Mobile can not be used during 88.2kHz or 96kHz operation, so EQ_ENA must be set to 0. The SYSCLK frequency is derived from MCLK. The maximum MCLK frequency is defined in the “Signal Timing Requirements” section. SAMPLE RATE REGISTER CONFIGURATION CLOCKING RATIO 88.2kHz SAMPLE_RATE = 101 CLK_SYS_RATE = 0001 (SYSCLK / fs = 128) BCLK_DIV = 00010 LRCLK_RATE = 040h SYSCLK = 128 x fs 96kHz SAMPLE_RATE = 101 CLK_SYS_RATE = 0001 (SYSCLK / fs = 128) BCLK_DIV = 00010 LRCLK_RATE = 040h SYSCLK = 128 x fs Table 67 DAC Operation at 88.2kHz and 96kHz Sample Rates For ADC operation at 88.2kHz or 96kHz sample rates, the available clocking configurations are detailed in Table 68. ADC operation at these sample rates is achieved by setting the SAMPLE_RATE field to half the required sample rate (eg. select 48kHz for 96kHz mode). For ADC operation at 88.2kHz or 96kHz sample rates, the DACs must both be disabled (DACL_ENA = 0 and DACR_ENA = 0). Note that ADC_OSR128, ADC_128_OSR_TST_MODE, and ADC_BIASX1P5 must be configured according to Table 68. The SYSCLK frequency is derived from MCLK. The maximum MCLK frequency is defined in the “Signal Timing Requirements” section. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |