55 / 60 page ![]() Data Sheet ADP5050 Rev. 0 | Page 55 of 60 Table 56. PWRGD Output Options Option Description Option 0 No monitoring of any channel Option 1 Monitor Channel 1 output (default) Option 2 Monitor Channel 2 output Option 3 Monitor Channel 1 and Channel 2 outputs Option 4 Monitor Channel 3 output Option 5 Monitor Channel 1 and Channel 3 outputs Option 6 Monitor Channel 2 and Channel 3 outputs Option 7 Monitor Channel 1, Channel 2, and Channel 3 outputs Option 8 Monitor Channel 4 output Option 9 Monitor Channel 1 and Channel 4 outputs Option 10 Monitor Channel 2 and Channel 4 outputs Option 11 Monitor Channel 1, Channel 2, and Channel 4 outputs Option 12 Monitor Channel 3 and Channel 4 outputs Option 13 Monitor Channel 1, Channel 3, and Channel 4 outputs Option 14 Monitor Channel 2, Channel 3, and Channel 4 outputs Option 15 Monitor Channel 1, Channel 2, Channel 3, and Channel 4 outputs Table 57. Output Discharge Functionality Options Option Description Option 0 Output discharge function disabled for all four buck regulators Option 1 Output discharge function enabled for all four buck regulators (default) Table 58. Switching Frequency Options for Channel 1 Option Description Option 0 1 × switching frequency set by the RT pin (default) Option 1 ½ × switching frequency set by the RT pin Table 59. Switching Frequency Options for Channel 3 Option Description Option 0 1 × switching frequency set by the RT pin (default) Option 1 ½ × switching frequency set by the RT pin Table 60. Pin 43—SYNC/MODE Pin Options Option Description Option 0 Forced PWM/automatic PWM/PSM mode setting with the ability to synchronize to an external clock (default) Option 1 Generate a clock signal equal to the master frequency set by the RT pin Table 61. Hiccup Protection Options for the Four Buck Regulators Option Description Option 0 Hiccup protection enabled for overcurrent events (default) Option 1 Hiccup protection disabled; frequency foldback protection only for overcurrent events Table 62. Short-Circuit Latch-Off Options for the Four Buck Regulators Option Description Option 0 Latch-off function disabled for output short-circuit events (default) Option 1 Latch-off function enabled for output short-circuit events |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |